1.1
This Standard applies to indoor or outdoor, open or enclosed, shunt power capacitors and assemblies of
shunt power capacitors with associated interconnections and supporting structures, for power factor
improvement and other applications on ac power systems having voltages up to 46 kV, designed to be
installed in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2
The…
STANDARD METHOD FOR FLAME TESTS OF FLAMERESISTANT FABRICS AND FILMS
1 SCOPE
1.1 These requirements apply to the performance in flame-exposure tests of flame-resistant fabrics of
natural, synthetic, or combinations of natural and synthetic fibres, or plastic films intended for such use as
tents, awnings, draperies, or decorations. The flame resistance of the fabric or film may be inherent in the
material used or may be the result of chemical treatment to…
Information technology — Universal Coded Character Set (UCS)
ISO/IEC 10646:2104 specifies the Universal Character Set (UCS). It is applicable to the representation, transmission, interchange, processing, storage, input and presentation of the written form of the languages of the world as well as additional symbols. It covers 120 585 characters from the world's scripts.
ISO/IEC 10646:2014:
specifies the architecture of ISO/IEC 10646;
defines terms…
Information technology - Universal Coded Character Set (UCS)
ISO/IEC 10646:2104 specifies the Universal Character Set (UCS). It is applicable to the representation, transmission, interchange, processing, storage, input and presentation of the written form of the languages of the world as well as additional symbols. It covers 120 585 characters from the world's scripts.
ISO/IEC 10646:2014:
specifies the architecture of ISO/IEC 10646;
defines terms…
Surface cleaning appliances - Floor treatment machines with or without traction drive, for commercia...
IEC 62826:2014 lists the characteristic performance parameters for walk-behind and ride-on floor scrubbers and sweepers and other floor cleaning machines according to IEC 60335-2-72. This standard does not apply to IEC 60312 series. The intent is to serve the manufacturers in describing parameters that fit in their manuals, and in their literature. This may include all or some of the parameters…
Buildings and constructed assets — Service life planning — Part 11: Terminology
ISO/TR 15686-11:2014 provides a compilation of the terms and definitions of concepts that have been standardized to establish a vocabulary applicable to the aspects of both the construction and use of a building or civil engineering works and the service life planning of the same, as applied in the documents of ISO/TC 59/SC 14 Design life.
ISO/TR 15686-11:2014 consists of terms and definitions…
Soils – Determination of the Coefficient of Permeability at the End of a Drill Casing
This standard specifies the test method used to determine the coefficient of permeability of the soil
in place at the end of a drill casing driven in by ramming.
NOTES —
1 This test method is particularly adapted for soils with a coefficient of permeability greater than
10-6 m/s.
2 The coefficient of permeability or hydraulic conductivity, in metres per second (m/s), is expressed by
the…
Soils – Determination of the Coefficient ofPermeability by the Lefranc Method
This standard specifies the test method used to determine the coefficient of permeability of the soil
in place around a cavity, named lantern, opened under the end of a drill casing driven by ramming.
NOTES —
1 This test method is particularly adapted for soils with a coefficient of permeability greater than
10-7 m/s.
2 The coefficient of permeability or hydraulic conductivity, in metres per…
STANDARD FOR DRY CHEMICAL FOR USE IN HAND ANDWHEELED FIRE EXTINGUISHERS
1.1 These requirements cover chemical, physical and performance properties of dry chemical fire
extinguishing agents for use in portable fire extinguishing equipment being evaluated to CAN/ULC-S504,
Standard for Dry Chemical Fire Extinguishers.
1.2 These requirements are also intended for the evaluation of recharge dry chemical fire extinguishing
agents for use in extinguishers meeting the…
1 Scope
1.1
This Standard applies to ac and dc motors with inherent overheating protection designed to be used in
accordance with the Canadian Electrical Code, Part I, as follows:
a) motors with a voltage rating not exceeding 600 V and with a protective device connected in the
motor circuit;
b) impedance-protected motors with a voltage rating not exceeding 600 V; and
c) motors with a…