1.1
This Standard applies to manual lever operated gas shut-off valves, sizes NPS ¼ inch to 8 inch, of metallic construction with welded, or flanged, or threaded ends other than pressure lubricated designs for use with natural gas, manufactured gas, and liquefied petroleum gases (distributed as vapour with or without the admixture of air), or mixtures thereof that are suitable for use between…
Periodic inspection of CANDU nuclear power plant balance of plant systems and components
1.1
This Standard defines requirements for the periodic inspection of balance of plant pressure retaining
systems, components, and supports that form part of a CANDU nuclear power plant using a risk
informed in-service inspection (RI-ISI) methodology. Periodic inspection (see Annex A for additional
guidance) is considered to include the fluid boundary portions of balance of plant systems,…
Aging management for concrete containment structures for nuclear power plants
1.1
This Standard provides aging management requirements for concrete containment structures and their
components for nuclear power plants and is directed to owners/operators, designers, manufacturers,
fabricators, and constructors.
Note: This Standard may provide guidance for aging management of other concrete structures where applicable.
1.2
This Standard provides requirements for aging…
Technical requirements for in-service evaluation of zirconium alloy pressure tubes in CANDU reactors
1.1
This Standard specifies the technical requirements for the owner/operator to ensure structural integrity
of cold-worked Zr-2.5 wt% Nb alloy pressure tubes in operating CANDU reactors. Clause 13 of CSA
N285.0/N285.6 Series requires that when in-service inspection results or material surveillance results do
not satisfy the requirements of the original inspection program, a fitness-for-…
1.1
This Standard applies to single- or multiple-conductor, round, flat, or coiled appliance wiring material
products classified as follows:
a) Class I — internal wiring of equipment (single- or multiple-conductor constructions with or without
an insulating covering, covering or jacket):
i) Group A — not subject to mechanical abuse; and
ii) Group B — potentially subject to mechanical abuse…
CAN/CSA-C22.2 No. 60601-2-17:15
Medical electrical equipment — Part 2-17: Particular requirements fo...
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
automatically-controlled BRACHYTHERAPY AFTERLOADING ME EQUIPMENT, hereafter referred to as
ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that…
1.1
This Standard applies to appliance plugs used as components of heater cord sets for use on cord- connected heating appliances rated for use on nominal single-phase system voltages of 240 V and less, designed to be used in dry nonhazardous locations in household and similar applications in accordance with the Canadian Electrical Code, Part I.
1.2
In this Standard, “shall” is used to express…
1.1
This Standard applies to Class 1, 2, 3, 4, 5, and 7 powered lift trucks—their design, operation, and maintenance. In addition, certain clauses apply to Class 6 vehicles, non-powered high-lift trucks, and personnel and burden carriers. See Annex B for a listing and description of classes.
1.2
The purpose of this Standard is to promote lift truck safety and minimize the risk of injury to…
1.1
This Standard specifies requirements and test procedures to determine the performance of stationary
electric signs that are hard wired.
Note: Background information on the scope and objective of this Standard is provided in Annex B.
1.2
This Standard applies to stationary electric signs for indoor or outdoor use, in nonhazardous locations,
intended for installation in accordance with the…
1.1
This Standard specifies requirements and test procedures to determine the performance of portable plug-in luminous signs.
Note: Background information on the scope and objective of this Standard is provided in Annex A.
1.2
This Standard applies to portable electric signs for indoor or outdoor use, in nonhazardous locations, intended for installation in accordance with the Canadian Electrical…