Medical electrical equipment - Part 2-87: Particular requirements for the basic safety and essential...
This document applies to the basic safety and essential performance of a high-frequency ventilator (HFV) in combination with its accessories, hereafter referred to as ME equipment:
- intended for use in an environment that provides specialized care for patients whose conditions can be life-threatening and who can require comprehensive care and constant monitoring in a professional healthcare…
Industrial furnaces and associated processing equipment — Safety requirements for steel converter an...
This document applies for new steel converter and its associated equipment (hereinafter referred to as converter plant) used in the process of carbon or stainless steel making as defined in 3.1 and illustrated in Annex B.
This document deals with significant hazards, hazardous situations and events relevant to the converter plant. It covers the intended use and foreseeable misuse.
This document…
Intelligent transport systems — Roadside modules SNMP data interface — Part 10: Variable message sig...
Variable message signs (VMSs) are installed in areas where traffic managers identify a frequent need to convey information to the travelling public, such as upstream from interchanges to alert the public to downstream congestion in time for them to alter their routes. This allows traffic managers to improve the efficiency, safety, and quality of traveller journeys.
In order to manage the…
Implementation Guideline for CSA Z1008, Management of impairment in the workplace, with a focus on i...
1 Scope
1.1 Inclusions
This Standard specifies requirements for management of impairment in the workplace while
providing specific requirements and guidance for impairment due to substance use, following
occupational health and safety management system (OHSMS) principles, as they apply to
a) development of a management of impairment in the workplace policy;
b) management commitment and…
1 Scope
1.1 Inclusions
This Standard specifies requirements for management of impairment in the workplace while providing specific requirements and guidance for impairment due to substance use, following occupational health and safety management system (OHSMS) principles, as they apply to
a)
development of a management of impairment in the workplace policy;
b)
management commitment and…
Electromagnetic compatibility (EMC) — Part 3-11: Limits — Limitation of voltage changes, voltage flu...
1 Scope
This part of IEC 61000 is concerned with the emission of voltage changes, voltage
fluctuations and flicker produced by equipment and impressed on the public low-voltage
supply system.
It specifies the limits of voltage changes produced by equipment tested under specified
conditions.
This document is primarily applicable to electrical and electronic equipment having a rated
input…
Glass-reinforced thermosetting plastics (GRP) pipes and fittings — Determination of the resistance t...
This document specifies a method for determining the chemical resistance properties of glass-reinforced thermosetting plastics (GRP) pipes and fittings in a deflected condition for nominal sizes DN 100 and larger.
In conjunction with ISO 10928, this document provides a method for evaluating the effect of a chemical environment on the interior of a pipe or fitting after a specified period of time…
Medical electrical equipment — Part 2-85: Particular requirements for the basic safety and essential...
This document applies to basic safety and essential performance of cerebral tissue oximeter equipment, that employs light at multiple wavelengths to derive a quantitative measure of oxygen saturation of haemoglobin within the volume of tissue sampled under the probe attached to the head. The cerebral tissue oximeter equipment can be based on continuous light, frequency domain or time domain…
Medical electrical equipment - Part 2-85: Particular requirements for the basic safety and essential...
This document applies to basic safety and essential performance of cerebral tissue oximeter equipment, that employs light at multiple wavelengths to derive a quantitative measure of oxygen saturation of haemoglobin within the volume of tissue sampled under the probe attached to the head. The cerebral tissue oximeter equipment can be based on continuous light, frequency domain or time domain…