Lung Ventilators for Medical Use - Particular Requirements for Basic Safety and Essential Performanc...
This National Standard of Canada is based on International Standard ISO 10651-2:2004.
1 Scope
IEC 60601-1:1988, Clause 1 applies, except as follows.
Amendment: This part of ISO 10651 specifies requirements for lung ventilators intended for home applications for those patients who are dependent on ventilatory support. Such ventilators are considered life-supporting equipment, are…
Household and similar electrical appliances - Safety - Part 2-8: Particular requirements for shavers...
This National Standard of Canada is based on International Standard CEI/IEC 60335-2-8:2005.
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric shavers, hair clippers and similar appliances intended for household and similar purposes, their rated voltage being not more than 250 V.
NOTE 101
Examples of similar appliances are…
Household and similar electrical appliances - Safety - Part 2-10: Particular requirements for floor ...
This National Standard of Canada is based on International Standard CEI/IEC 60335-2-10:2005.
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric floor treatment and wet scrubbing machines intended for household and similar purposes, their rated voltage being not more than 250 V.
NOTE 101
Examples of floor treatment machines…
Vehicles, Boats, and Internal Combustion Engine Driven Devices-Radio Disturbance Characteristics-Lim...
This National Standard of Canada is based on International Standard CEI/IEC CISPR 12, fifth edition, 2001-09).
1 Scope
The limits in this International Standard are designed to provide protection for broadcast receivers in the frequency range of 30 MHz to 1 000 MHz when used in the residential environment.
Compliance with this standard may not provide adequate protection for new types of radio…
Household and Similar Electrical Appliances - Safety - Part 2-9: Particular Requirements for Grills,...
This National Standard of Canada is based on CEI/IEC 60335-2-9:2002 + A1:2004.
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric portable appliances for household purposes that have a cooking function such as baking, roasting and grilling, their rated voltage being not more than 250 V.
NOTE 101
Examples of appliances that…
Medical Electrical Equipment - Part 2-4: Particular Requirements for the Safety of Cardiac Defibrill...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-4:2002.
1 Scope and object
This clause of the General Standard applies except as follows:
*1.1 Scope Addition:
This Particular Standard specifies requirements for the safety of CARDIAC DEFIBRILLATORS as defined in 2.1.101, hereinafter referred to as EQUIPMENT.
This Particular Standard does not apply to…
Medical electrical equipment - Part 1-2: General requirements for safety - Collateral standard: Elec...
This National Standard of Canada is equivalent to International Standard IEC 60601-1-2:2001 (second edition, 2001-09).
1 Scope and object
1.201 Scope
This standard applies to ELECTROMAGNETIC COMPATIBILITY of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereinafter referred to as EQUIPMENT and SYSTEMS, respectively.
1.202 Object
This standard specifies requirements and tests for…
Medical electrical equipment - Part 2-17: Particular requirements for the safety of automatically-co...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-17:04, second edition.
1 Scope and object
This clause of the General Standard applies except as follows:
1.1 Scope
Addition:
1.1.101 This Particular Standard specifies requirements for the safety of automaticallycontrolled
EQUIPMENT for BRACHYTHERAPY of patients using AFTERLOADING techniques.
1.1.102 This…
Medical Electrical Equipment - Part 2-5: Particular Requirements for the Safety of Ultrasonic Physio...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-5:2000.
1.1 Scope
Addition:
This Particular Standard specifies the requirements for safety of ULTRASONIC PHYSIOTHERAPY EQUIPMENT used in medical practice, as defined in 2.1.101.
This Particular Standard does not apply to:
- EQUIPMENT in which a tool is driven by ULTRASOUND (for example EQUIPMENT…
Backwater Valves and Check Valves Made of Cast
Iron or Thermoplastic Used in Drainage Systems -
Char...
SCOPE
This standard applies to backwater valves designed to be used in drainage systems (see note) and to
check valves designed to be used in drainage systems that do not drain by gravity to the building
sewer, in compliance with the requirements of the National Plumbing Code of Canada - 2005.
NOTE - The National Plumbing Code of Canada - 2005 defines the term drainage system as follows:
"…