Household and similar electrical appliances — Safety — Part 2-70: Particular requirements for milkin...
This National Standard of Canada is based on International Standard CEI/IEC 60335-2-70:2004.
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of milking machines, to be used in stalls and in the open, that are designed for milking farm animals, such as cows, the rated voltage of the milking machine being not more than 250 V for…
Safety of Machinery - Electro-sensitive Protective Equipment - Part 2: Particular Requirements for E...
This National Standard of Canada is based on International Standard CEI/IEC 61496-2:1997.
1 Scope
This clause of part 1 is replaced by the following: This part of IEC 61496 specifies requirements for the design, construction and testing of electro-sensitive protective equipment (ESPE) for the safeguarding of machinery, employing active opto-electronic protective devices (AOPDs) for the…
STANDARD FOR
ABOVEGROUND STEEL CONTAINED TANK
ASSEMBLIES FOR FLAMMABLE AND
COMBUSTIBLE LIQUIDS
1. SCOPE
1.1 This Standard covers steel contained tank assemblies that are used for
aboveground storage of flammable and combustible liquids such as gasoline, fuel oil, or similar
products with a relative density not greater than 1.0.
1.2 Contained tank assemblies consist of primary tanks contained within steel
containments having capacities of not less than 110% of the capacities of the…
Appareils électrodomestiques et analogues - Sécurité - Partie 2-55: Règles particulières pour les ap...
La presente norme nationale du Canada est équivalente a la norme internationale IEC 60335-2-55:2005.
1 Scope
This clause of Part 1 is replaced by the following.
This International Standard deals with the safety of electric appliances for use with aquariums and garden ponds for household and similar purposes, their rated voltage being not more
than 250 V.
NOTE 101 Examples of…
1 Domaine d'application
1.1
Cette norme s'applique aux disjoncteurs différentiels monophasés et triphasés de classe A conçus pour la protection du personnel, destinés à être utilisés exclusivement dans des systèmes à neutre mis à la terre conformément au National Electrical Code (NEC), ANSI/NFPA 70, au Code canadien de l'électricité (CCÉ), C22.1, ainsi qu'à la Standard for…
This CSA Standard is a joint Standard with UL 62, and ANCE NMX-J-436.
1 Scope
1.1 General
This standard specifies the requirements for flexible cords, elevator cables, and hoistway cables, rated 600 V maximum, and intended for use in accordance with CSA C22.1, Canadian Electrical Code (CEC), Part I and CAN/CSA-C22.2 No. 0, General Requirements - Canadian Electrical Code, Part II, in Canada…
La présente norme CSA est commune avec UL 486C et NXJ-548-ANCE.
1 Domaine d'application
1.1
Cette norme s'applique aux serre-fils et aux connecteurs de câble posés à la main ou à l'aide d'un outil et destinés à tous les conducteurs en alliage de cuivre ou d'aluminium (ou les deux), conformément à la norme canadienne CSA C22.1, Code canadien de l'électricité,…
Electromagnetic Compatibility (EMC) - Part 4-4: Testing and Measurement Techniques - Electrical Fast...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-4-4:2004 second edition, 2004-07.
1 Scope
This part of IEC 61000-4 relates to the immunity of electrical and electronic equipment to repetitive electrical fast transients. It gives immunity requirements and test procedures related to electrical fast transients/bursts. It additionally defines ranges of test…
Electromagnetic Compatibility (EMC) - Part 4-34: Testing and Measurement Techniques - Voltage Dips, ...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-4-34:2005.
1 Scope
This part of IEC 61000 defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations.
This standard applies to electrical and…
Low Voltage Transformers - Part 1: General Requirements
This CSA Standard is a bi-national Standard with UL 5085-1.
1 Scope
1.1
These requirements cover the following types of transformers:
a) Air-cooled transformers and reactors for general use;
b) General purpose autotransformers;
c) Ferroresonant transformers;
d) Class 2 and Class 3 transformers (which are evaluated in accordance with Part 3);
e) Cord-connected transformers (which are…