Fixed capacitors for use in electronic equipment. Part 15: Sectional specification: Fixed tantalum c...
Applies to polar and bipolar tantalum electrolyte. Capacitors with
solid and non-solid electrolyte for use in electronic equipment.
Prescribes preferred ratings and characteristics and selects from
IEC 60384-1 (1982) the appropriate quality assessment procedures,
tests and measuring methods and gives general performance
requirements for this type of capacitor. This publication replaces
IEC 60361…
Condensateurs fixes utilisés dans les équipements électroniques. Quinzième partie: Spécification int...
S'applique aux condensateurs au tantale polarisés et non polarisés à
électrolyte solide et à électrolyte non solide utilisés dans les
équipements électroniques. Prescrit les valeurs préférentielles et
les caractéristiques, choisit dans la CEI 60384-1 les procédures
d'assurance de la qualité et les méthodes d'essai et de mesures
appropriées et fixe les exigences générales pour ce…
Electrical apparatus for explosive gas atmosphere - Part 13: Construction and use of rooms or buildi...
Applies to rooms and buildings containing electrical apparatus and protected by internal overpressure against the ingress of explosive external atmosphere. Includes recommendations for the construction, equipping and operation of such rooms or buildings and their associated parts. Gives tests to show the conformity with these recommendations and indicates the marking to be placed on the rooms or…
Matériel électrique pour atmosphères explosives gazeuses - Partie 13: Construction et exploitation d...
S'applique aux salles ou bâtiments contenant du matériel électrique et protégés par surpression interne contre la pénétration de l'atmosphère explosive extérieure. Comprend les recommandations de construction, d'aménagement et d'exploitation des salles ou bâtiments et de leurs éléments associés. Recommande les épreuves nécessaires pour montrer que l'installation est…
Radio interference characteristics of overhead power lines and high-voltage equipment. Part 1: Descr...
This publication applies to radio noise from overhead power lines
and high voltage equipment which may cause interference to radio
reception, excluding the fields from power line carrier signals.
The frequency range covered is 0.15 MHz to 300 MHz. The purpose of
Part 1 is to discuss the physical phenomena
involved in the generation of electromagnetic noise fields; it also
includes the main…
Guidelines for the Development of Limit States Design
1. Scope
1.1 This Publication sets forth a recommended common basis for codes and standards for the design and evaluation of civil engineering structures, such as building and industrial structures, bridges, earth and water-retaining structures, towers, chimneys, and poles, with the objective of ensuring an adequate and consistent treatment of safety and serviceability whatever the material…
Filtres à air non nettoyables à élément filtrant plissé pourvu de séparateurs de plis multiples
Exigences quant aux dimensions, aux caractéristiques et aux méthodes d'essai relatives aux filtres à air non nettoyables à élément filtrant plissé pourvu de séparateurs multiples, destinés à être utilisés dans les conditions où les poussières atmosphériques sont généralement de dimensions inférieures à 5 micromètres. La présente norme s'applique aux filtres à air équipant les…
Exigences relatives aux systèmes d'arrêt des centrales nucléaires CANDU
1. Domaine d'application
1.1 La présente norme porte surtout sur la sûreté nucléaire des systèmes d'arrêt, c'est-à-dire leur capacité de mettre fin à une réaction nucléaire lorsqu'il y a possibilité de danger. Elle reconnaît toutefois que des déclenchements inutiles répétés du système d'arrêt ne font que fatiguer indûment la centrale nucléaire et risquent même d…