Unités mobiles et fixes en mer - Installations électriques - Partie 3: Equipement
L'IEC 61892-3:2019 s'applique aux équipements électriques dans les unités mobiles et fixes en mer, y compris les canalisations, les stations de pompage ou de raclage, les stations de compression et les systèmes d'amarrage à point unique, qui sont utilisés dans l'industrie pétrolière en mer (offshore) pour le forage, la production, les lieux d'habitation, le traitement, le…
Mobile and fixed offshore units - Electrical installations - Part 6: Installation
IEC 61892-6:2019 provides specific requirements for the installation of electrical equipment in mobile and fixed offshore units, including pipeline, pumping or "pigging" stations, compressor stations and single buoy moorings, used in the offshore petroleum industry for drilling, production, accommodation, processing, storage and offloading purposes.
It applies to all installations,…
Unités mobiles et fixes en mer - Installations électriques - Partie 6: Installation
L'IEC 61892-6:2019 donne les exigences spécifiques relatives à l'installation des équipements électriques dans les unités mobiles et fixes en mer, y compris les canalisations, les stations de pompage ou de raclage, les stations de compression et les systèmes d'amarrage à point unique, qui sont utilisés dans l'industrie pétrolière en mer (offshore) pour le forage, la production…
Mobile and fixed offshore units - Electrical installations - Part 7: Hazardous areas
IEC 61892-7:2019 provides requirements for hazardous area classification and selection of electrical equipment and installation in hazardous areas in mobile and fixed offshore units, including pipeline, pumping or "pigging" stations, compressor stations and single buoy moorings, used in the offshore petroleum industry for drilling, production, accommodation, processing, storage and…
Unités mobiles et fixes en mer - Installations électriques - Partie 7: Emplacements dangereux
L'IEC 61892-7:2019 donne les exigences relatives à la classification des espaces dangereux et au choix des équipements et installations électriques dans les emplacements dangereux dans les unités mobiles et fixes en mer, y compris les canalisations, les stations de pompage ou de raclage, les stations de compression et les systèmes d'amarrage à point unique, qui sont utilisés dans l…
Industrial trucks — Specifications for indicator lights for container handling and grappler arm oper...
This document specifies requirements for indicator lights to show the status of freight-container-handling spreaders and grappler arms.
It is applicable to:
a) container-handling spreaders with twistlocks for handling unladen and/or laden freight containers;
b) grappler (bottom lift) arms for handling semi-trailers and swap bodies;
when fitted to:
— counterbalance lift trucks, with…
Ferrite cores - Guidelines on dimensions and the limits of surface irregularities - Part 14: EFD-cor...
IEC 63093-14:2019 specifies the dimensions that are of importance for mechanical interchangeability for a preferred range of EFD-cores, the essential dimensions of coil formers to be used with them, and the effective parameter values to be used in calculations involving them. It also gives guidance on the allowable limits of surface irregularities applicable to EFD-cores in accordance with the…
Noyaux ferrites - Lignes directrices relatives aux dimensions et aux limites des irrégularités de su...
L’IEC 63093-14:2019 spécifie les dimensions qui présentent une importance pour l'interchangeabilité mécanique d'une plage préférentielle de noyaux EFD, les dimensions essentielles des supports de bobine à utiliser avec les noyaux EFD, ainsi que les valeurs des paramètres effectifs à utiliser dans les calculs qui impliquent ces noyaux. Elle donne également des recommandations relatives…
Standard for Pre-Engineered Dry and Wet Chemical Extinguishing System
1 Scope
1.1 These requirements cover the construction and operation of fixed pre-engineered dry chemical fire extinguishing system units and fixed automatic extinguisher units intended to be used in accordance with the Standard for Dry Chemical Extinguishing Systems, NFPA 17 and with the National Fire Code of Canada, asapplicable; and; fixedpre-engineered wet chemical fireextinguishing system…
Impedance heating of pipelines and equipment — Application guide for design, installation, testing, ...
This standard provides for the application of impedance heating systems for steel or steel alloy pipe and
equipment. It provides recommendations for design, installation, maintenance, and repair of these systems
in general industry applications.
This standard applies to impedance heating systems intended to be installed in ordinary and hazardous
locations with explosive atmospheres. The…