Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 282: ...
IEC 60684-3-282:2025 gives the requirements for two types of heat-shrinkable, polyolefin sleeving, stress control, not flame retarded, with a nominal shrink ratio up to 3:1.
This sleeving has been found suitable for use up to temperatures of 100 °C.
Type A: Medium wall Internal diameter up to 65,0 mm typically
Type B: Thick wall Internal diameter up to 95,0 mm typically
Since these types of…
Flexible insulating sleeving - Part 3: Specifications for individual types of sleeving - Sheet 282: ...
IEC 60684-3-282:2025 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60684-3-282:2025 gives the requirements for two types of heat-shrinkable, polyolefin sleeving, stress control…
Dentistry — Artificial intelligence (AI) and augmented intelligence (AuI) based 2D radiograph analys...
This document defines the requirements for developing and documenting the goals, limitations, target end users and target patient population for artificial intelligence (AI) and augmented intelligence (AuI) enabled 2D radiograph analysis software for dentistry applications. It outlines the requirements for appropriate training data, validation data, test data and annotation for the software to…
Information technology — Automatic identification and data capture techniques — Data Matrix Rectangu...
This document defines the requirements for the symbology known as Data Matrix Rectangular Extension (DMRE). This document specifies the DMRE code symbology characteristics, data character encodation, symbol formats, dimensions and print quality requirements, error correction rules, decoding algorithm, and user-selectable application parameters.
This document applies to all DMRE code symbols…
Information technology - Automatic identification and data capture techniques - Data Matrix Rectangu...
This document defines the requirements for the symbology known as Data Matrix Rectangular Extension (DMRE). This document specifies the DMRE code symbology characteristics, data character encodation, symbol formats, dimensions and print quality requirements, error correction rules, decoding algorithm, and user-selectable application parameters.
This document applies to all DMRE code symbols…
Information technology – Implementation and operation of customer premises cabling – Part 5: Sustain...
ISO/IEC 14763-5:2025 specifies requirements and recommendations to maximize the sustainability of cabling systems including both customer premises infrastructure and the accommodation of information technology equipment by addressing the
a) cabling design;
b) selection, packaging and transportation of components and related materials;
c) installation, operation and maintenance;
d) management…
PPE for firefighters — Test methods and requirements for PPE used by firefighters who are at risk of...
This document specifies the minimum design and performance requirements for clothing as part of personal protective equipment (PPE) to be used by firefighters, primarily but not solely to protect against exposure to flame and high thermal loads, and particulates (including other products of combustion).
To assist with choice based on user risk assessment, a single level of heat and flame…
Graphical symbols for diagrams — Part 2: Graphical symbols
This document specifies graphical symbols for diagrams related to industrial components, products and processing.
This document constitutes a symbol library, from which users can use the symbols or created symbol examples for use in diagrams (see Tables 1 to 149).
General rules and guidance for the preparation and presentation of graphical symbols are given in ISO 14617-1. Application rules for…
High-voltage test techniques - Part 2: Measuring systems
IEC 60060-2:2025 is applicable to complete measuring systems and to their components, used for the measurement of high voltages during laboratory and factory tests with direct voltage, alternating voltage and lightning and switching impulse voltages and combined and composite voltages as specified in IEC 60060-1. For measurements during on-site tests, see IEC 60060-3. The limits on uncertainties…
High-voltage test techniques - Part 2: Measuring systems
IEC 60060-2:2025 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60060-2:2025 is applicable to complete measuring systems and to their components, used for the measurement of…