Effective Sterilization in Health Care Facilities by the Ethylene Oxide Process
1. Scope
Caution: ETHYLENE OXIDE IN LIQUID AND VAPOUR FORM IS ACUTELY TOXIC AND HAS BEEN
CLASSIFIED AS A HUMAN CARCINOGEN BY THE INTERNATIONAL AGENCY FOR RESEARCH ON
CANCER. FOR PROVISION OF ADEQUATE PROTECTION AGAINST THESE EFFECTS, REFER TO
FEDERAL AND PROVINCIAL REGULATIONS AND TO CSA STANDARD Z314.9.
1.1
This Standard outlines essential elements in a program for using ethylene…
Effective Sterilization in Health Care Facilities by the Steam Process
1. Scope
1.1
This Standard outlines essential elements in a program for using steam to sterilize medical devices in health care facilities, with the object of achieving an adequate level of sterility assurance and minimizing the risk of injury to the operators of steam sterilization equipment.
Notes:
(1) The term "health care facilities" includes, but is not limited to,…
Industrial automation systems and integration — Product data representation and exchange — Part 23: ...
This part of ISO 10303 specifies the implementation of the functional interface specified in the standard
data access interface (SDAI), ISO 10303-22, in the C++ programming language.
The following are within the scope of this part of ISO 10303:
— access to and manipulation of data types and entities which are specified in ISO 10303-22;
— convenience functions suitable to this language binding;
—…
Industrial automation systems and integration — Product data representation and exchange — Part 27: ...
This part of ISO 10303 specifies a binding of the Java1) programming language to application data
modelled in EXPRESS, ISO 10303-11 and to the standard data access interface, ISO 10303-22. It also
specifies an import and export mechanism for data according to the clear text encoding of the exchange
structure, ISO 10303-21. A further extension is that SDAI repositories can be created, deleted and…
Scope
General
This guideline incorporates ergonomics into a step-by-step process for the
optimal design of office systems, including the design of jobs and work
organization, layout of the office, environmental conditions, and workstation
design. It is intended predominately for office workers and employers who are
responsible for health and safety or ergonomics programs in the…
Industrial automation systems — Numerical control of machines — NC processor output — Post processor...
This International Standard defines the elements of a set of
post processor statements to be used in numerical control
software. These statements are encoded on 2 000 class
and 20 000 class CLDATA records or their equivalent.
Each processor using one of the ISO numerical control
programming languages shall be capable of producing post
processor command type CLDATA records as defined in
this…
IEC 61131-5:2000 specifies communication aspects of a programmable controller. It specifies from the viewpoint of a PC how any device can communicate with a PC as a server and how a PC can communicate with any device. In particular, it specifies the behavior of the PC as it provides services on behalf of other devices and the services the PC application program can request from other devices.…
IEC 61131-5:2000 specifies communication aspects of a programmable controller. It specifies from the viewpoint of a PC how any device can communicate with a PC as a server and how a PC can communicate with any device. In particular, it specifies the behavior of the PC as it provides services on behalf of other devices and the services the PC application program can request from other devices.…