Measurement of radioactivity in the environment — Soil — Part 1: General guidelines and definitions
This document specifies the general requirements to carry out radionuclides tests, including sampling of soil including rock from bedrock and ore as well as of construction materials and products, pottery, etc. using NORM or those from technological processes involving Technologically Enhanced Naturally Occurring Radioactive Materials (TENORM) e.g. the mining and processing of mineral sands or…
Water quality — Detection and enumeration of thermotolerant Campylobacter spp
This document specifies a method for the detection, semi-quantitative and quantitative (MPN) enumeration of thermotolerant Campylobacter species.
The method can be applied to all kinds of waters including: drinking water, ground water and well water, fresh, brackish and saline surface water, swimming pools, spa and hydrotherapy pools, recreational waters, agricultural waters and runoff,…
Testing of concrete — Part 14: Setting time of concrete mixtures by resistance to penetration
This document covers the method for determining the setting time of concrete with slump greater than zero, by testing mortar sieved from the concrete mixture. The initial setting time and the final setting time are the time intervals required for the mortar sieved from the concrete mixture to reach the specified values of penetration resistance after the initial contact of cement and water.
The…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-01...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
This part of IEC 61010 specifies safety requirements for electrically powered laboratory
equipment for the heating of materials, where the heating of materials is one of the functions
of the equipment.
NOTE If all or part of the equipment falls within the scope of one or…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text by the following:
This part of IEC 61010 applies to automatic and semi-automatic laboratory equipment for
analysis and other purposes.
Automatic and semi-automatic laboratory equipment consists of instruments or systems for
measuring or modifying one or…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-10...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text, except the first paragraph, with the following new text:
This part of IEC 61010 applies to equipment intended for in vitro diagnostic (IVD) medical
purposes, including self-test IVD medical purposes.
IVD medical equipment, whether used alone or in…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1 Scope
1.1.1 Equipment included in scope
Replacement:
Replace the text, except the first paragraph, with the following new text:
This part of IEC 61010 applies to electrically powered laboratory atomic spectrometers with
thermal atomization.
NOTE 1 Examples include atomic absorption spectrometers, emission flame…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text, except the first paragraph, with the following new text:
This part of IEC 61010 is applicable to electrically operated laboratory equipment and its
accessories for mechanical mixing and stirring, where mechanical energy influences the
shape or size or…
Plastics — Smoke generation — Determination of the corrosivity of fire effluents — Part 1: General c...
The document defines terms related to smoke corrosivity as well as smoke acidity and smoke toxicity. It presents the scenario-based approach that controls smoke corrosivity. It describes the test methods to assess smoke corrosivity at laboratory scale and deals with test applicability and post-exposure conditions. This document is applicable to tests of determination of smoke corrosivity from…
Determination of pH value — Technical buffer solutions for the calibration of technical measuring in...
This document specifies requirements for technical buffer solutions. These buffer solutions are preferably used for the calibration and adjustment of technical pH measuring equipment as well as pH measuring installations in laboratories. Measuring methods are given to determine pH values and buffer capacities of such buffer solutions based on pH reference buffer solutions in accordance with ISO…