Accuracy (trueness and precision) of measurement methods and results — Part 2: Basic method for the ...
1.1 This document
— amplifies the general principles for designing experiments for the numerical estimation of the precision of measurement methods by means of a collaborative interlaboratory experiment;
— provides a detailed practical description of the basic method for routine use in estimating the precision of measurement methods;
— provides guidance to all personnel concerned…
Metallic powders — Determination of envelope-specific surface area from measurements of the permeabi...
This document specifies a method of measuring the air permeability and the porosity of a packed bed of metal powder, and of deriving therefrom the value of the envelope-specific surface area. The permeability is determined under steady-state flow conditions, using a laminar flow of air at a pressure near atmospheric. This document does not include the measurement of permeability by a constant…
Hand-held portable power tools — Test methods for evaluation of vibration emission — Part 1: Angle a...
This document specifies a laboratory method for measuring hand-transmitted vibration emission at the handles of hand-held power-driven angle and vertical grinders. It is a type-test procedure for establishing the magnitude of vibration in the gripping areas of a machine fitted with a specified test wheel and run under no‑load conditions. The method has been established for surface grinding tasks…
Measurement of radioactivity in the environment — Soil — Part 1: General guidelines and definitions
This document specifies the general requirements to carry out radionuclides tests, including sampling of soil including rock from bedrock and ore as well as of construction materials and products, pottery, etc. using NORM or those from technological processes involving Technologically Enhanced Naturally Occurring Radioactive Materials (TENORM) e.g. the mining and processing of mineral sands or…
Flexible and rigid cellular polymeric materials — Accelerated ageing tests
This document specifies, for flexible and rigid cellular polymeric materials, laboratory procedures which are intended to imitate the effects of naturally occurring reactions such as oxidation or hydrolysis by humidity. The physical properties of interest are measured before and after the application of the specified treatments.
Test conditions are only given for open cellular latex, both open-…
Safety requirements for electrical equipment for measurement, control and laboratory use — Part 2-01...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
This part of IEC 61010 specifies safety requirements for electrically powered laboratory
equipment for the heating of materials, where the heating of materials is one of the functions
of the equipment.
NOTE If all or part of the equipment falls within the scope of one or…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1 Scope
[Add the following]
This Standard applies to the above-noted equipment that is intended to be installed or used in
accordance with CSA C22.1, Canadian Electrical Code, Part I.
General requirements applicable to this Standard are provided in CAN/CSA-C22.2 No. 0.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1 Scope
1.1.1 Equipment included in Scope
[Add the following]
This Standard applies to the above-noted equipment that is intended to be installed or used in
accordance with CSA C22.1, Canadian Electrical Code, Part I.
General requirements applicable to this Standard are provided in CAN/CSA-C22.2 No. 0.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of part 1 is applicable except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text by the following:
This part of IEC 61010 applies to automatic and semi-automatic laboratory equipment for
analysis and other purposes.
Automatic and semi-automatic laboratory equipment consists of instruments or systems for
measuring or modifying one or…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable, except as follows:
1.1.1 Equipment included in scope
Replacement:
Replace the text with the following:
This part of IEC 61010 specifies particular safety requirements for CABINET X-RAY SYSTEMS.
A CABINET X-RAY SYSTEM is a system that contains an X-ray tube installed in a cabinet which,
independently of existing architectural…