Metallic tube connections for fluid power and general use — Part 1: 24 degree compression fittings
Specifies general (pressure, temperature, designation, assembly, marking) and dimensional requirements for the design and performance of 24° compression fittings which are suitable for use with ferrous and non-ferrous tubes with outside diameters from 4 mm to 42 mm, inclusive. These fittings are for use in fluid power and general applications within the limits of pressure and temperature…
Information technology — International Standardized Profile TAnnnn — Connection-mode Transport Servi...
ISO/IEC ISP 10608 is applicable to end systems concerned with operating in the open systems interconnection (OSI) environment. It specifies a combination of OSI standards which collectively provide the connection-mode transport service using the connectionless network service. This part is applicable to the provision of the connection-mode transport service in end systems attached to a token ring…
Information technology — International Standardized Profile TAnnnn — Connection-mode Transport Servi...
Is applicable to end systems or relay systems operating over token ring LAN subnetworks in the open systems interconnection (OSI) environment. Relates to any of the transport (Tx, Ux) or relay (Rx) profiles defined in ISO/IEC TR 10000-2, where such profile uses subnetwork type 53. Specifically, provides a common set of requirements that are applicable to transport groups TA, TB, TC, TD, TE, UA,…
1.1
This standard applies to asbestos-cement, nonpressure, small-diameter pipe,
suitable for use as building sewer pipe and as building drain pipe buried under
the floor.
1.2
For cautionary notes on cutting, sanding, grinding or drilling of this product,
see par. 6.2.2 and 8.3.
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
This National Standard of Canada is based on International Standard IEC 1010-2-031:1993.
1. Scope and Object This clause of part 1 is applicable except as follows:
1.1 Scope Replacement:
This Particular Standard specifies requirements for the safety of hand-held and hand-manipulated probe assemblies designed to be used with equipment installed and used in accordance with the Rules…
Hydraulic fluid power — Four-screw split-flange connections for use at pressures of 2,5 MPa to 40 MP...
Gives complete general and dimensional specifications. For flange connections, a minimum design factor of 2,5 is valid with screws of property class 8.8, not including weld joints, for which special instructions exist. The design factor of the flange may be increased to 3,5 or better by using flange-head screws of property class 10.9. Also includes appropriate references to the O-ring seals and…
Hydraulic fluid power — Four-screw, one-piece square-flange connections for use at pressures of 25 M...
Gives complete general and dimensional specifications. For flange connections, a design factor of 2,5 is valid, not including weld joints, for which special instructions exist. Also specifies the dimensions of the seals to be used, as well as the grooves to house the seals.
Specifies dimensions necessary for the mounting and interchangeability of flange-mounted fuel injectors, containing the nozzles specified in ISO 2697. The location of the fuel inlet and leak-off connections are not defined since they vary according to the particular application.
Site Preparation, Foundation, and Anchorage of Mobile Homes
1.1
This Standard applies to mobile homes or modular units designed to be supported
on longitudinal floor beams.
Note: For simplicity, the term mobile home is used in the text of this
Standard.
1.2
This Standard includes requirements for the following aspects of mobile home
installation:
(a) site preparation;
(b) foundations;
(c) anchorage;
(d) connection of multiple-section units;…