Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 2291 - 2300 de 6048
Interior air of road vehicles — Part 5: Screening method for the determination of the emissions of v...
ISO 12219-5:2014 specifies a chamber based, static headspace type method for measuring volatile organic compounds (VOCs), formaldehyde and other carbonyl compounds which may diffuse from vehicle interior unit components into the cabin air. The chamber emission test is intended to provide characteristic emission of unit component to car interior of assembly level emission. It also specifies the…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2014-05-18
Code(s) de l'ICS :
13.040.20; 43.020
Electromagnetic compatibility (EMC) - Part 4-5: Testing and measurement techniques - Surge immunity ...
IEC 61000-4-5:2014 relates to the immunity requirements, test methods, and range of recommended test levels for equipment with regard to unidirectional surges caused by over-voltages from switching and lightning transients. Several test levels are defined which relate to different environment and installation conditions. These requirements are developed for and are applicable to electrical and…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2014-05-14
Code(s) de l'ICS :
33.100.20
Compatibilité électromagnétique (CEM) - Partie 4-5: Techniques d'essai et de mesure - Essai d&#...
L'IEC 61000-4-5:2014 se rapporte aux exigences d'immunité pour les matériels, aux méthodes d'essai et à la gamme des niveaux d'essai recommandés, vis-à-vis des ondes de choc unidirectionnelles provoquées par des surtensions dues aux transitoires de foudre et de man uvre. Elle définit plusieurs niveaux d'essai se rapportant à différentes conditions d'environnement et…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2014-05-14
Code(s) de l'ICS :
33.100.20
Medical electrical equipment — Part 2-67: Particular requirements for basic safety and essential per...
ISO 80601-2-67:2014 is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as me equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home healthcare environment. Oxygen conserving equipment is…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2014-05-13
Code(s) de l'ICS :
11.040.10
Information technology - Multimedia application format (MPEG-A) — Part 13: Augmented reality applica...
ISO/IEC 23000-13:2014 specifies: scene description elements for representing augmented reality content; mechanisms to connect to local and remote sensors and actuators; mechanisms to integrated compressed medias (image, audio, video, graphics); mechanisms to connect to remote resources such as maps and compressed medias.
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2014-05-13
Code(s) de l'ICS :
35.040.40
Information technology - Multimedia application format (MPEG-A) - Part 13: Augmented reality applica...
ISO/IEC 23000-13:2014 specifies: scene description elements for representing augmented reality content; mechanisms to connect to local and remote sensors and actuators; mechanisms to integrated compressed medias (image, audio, video, graphics); mechanisms to connect to remote resources such as maps and compressed medias.
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2014-05-13
Code(s) de l'ICS :
35.040.40
Medical electrical equipment -- Part 2-67: Particular requirements for basic safety and essential pe...
ISO 80601-2-67:2014 is applicable to the basic safety and essential performance of oxygen conserving equipment, hereafter referred to as me equipment, in combination with its accessories intended to conserve supplemental oxygen by delivering gas intermittently and synchronized with the patient's inspiratory cycle, when used in the home healthcare environment. Oxygen conserving equipment is…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2014-05-13
Code(s) de l'ICS :
11.040.10
Safety and control devices for gas burners and gas-burning appliances — Particular requirements — Pa...
ISO 23551-5:2014 specifies safety, constructional and performance requirements for manual gas valves intended for use with gas burners and gas-burning appliances, hereafter referred to as ?valves', unless otherwise specified. ISO 23551-5:2014 applies to following types of manual gas valves: manual gas shut-off valve; gas burner valve; appliance connector valve; "delta C" valve.…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2014-05-07
Code(s) de l'ICS :
27.060.20
Radio-frequency connectors - Part 49: Sectional specification for SMAA series R.F. connectors
IEC 61169-49:2014 which is a sectional specification (SS), provides information and rules for the preparation of detail specifications (DS) for type SMAA series thread mated coaxial connectors. The connectors are normally used for micro wave applications, connecting with 50 Ohms RF cables or microstrips in an operating range up to 27 GHz. These connectors can be intermated with SMA (IEC 60169-15…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2014-05-07
Code(s) de l'ICS :
33.120.30
Photovoltaic devices - Part 8: Measurement of spectral responsivity of a photovoltaic (PV) device
IEC 60904-8:2014 specifies the requirements for the measurement of the spectral responsivity of both linear and non-linear photovoltaic devices. The spectral responsivity of a photovoltaic device is used in cell development and cell analysis, as it provides a measure of recombination and other processes occurring inside the semiconductor or cell material system. The main technical changes with…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2014-05-07
Code(s) de l'ICS :
27.160

Spacer