Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 1781 - 1790 de 5905
Non-sewered sanitation systems — General safety and performance requirements for design and testing
IWA 24:2016 specifies technical requirements, test methods, and sustainability considerations for non-sewered sanitation systems. A non-sewered sanitation system, for the purposes of this document, is a sanitation system that 1) is not connected to a networked sewer system and 2) collects, conveys, and fully treats the specific input, to allow for safe reuse or disposal of the generated output.…
Éditeur :
ISO
Statut :
Annulée
Date de publication :
2016-08-29
Code(s) de l'ICS :
13.020.20; 91.140.70
Road vehicles — Local Interconnect Network (LIN) — Part 4: Electrical physical layer (EPL) specifica...
ISO 17987-4:2016 specifies the 12 V and 24 V electrical physical layers (EPL) of the LIN communications system. The electrical physical layer for LIN is designed for low-cost networks with bit rates up to 20 kbit/s to connect automotive electronic control units (ECUs). The medium that is used is a single wire for each receiver and transmitter with reference to ground. ISO 17987-4:2016 includes…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2016-08-24
Code(s) de l'ICS :
43.040.15
Universal serial bus interfaces for data and power - Part 1-3: Universal Serial Bus interfaces - Com...
IEC 62680-1-3:2016(E) defines the USB Type-C™ receptacles, plug and cables. It defines a new receptacle, plug, cable and detection mechanisms that are compatible with existing USB interface electrical and functional specifications. This specification covers the following aspects that are needed to produce and use this new USB cable/connector solution in newer platforms and devices, and that…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2016-08-16
Code(s) de l'ICS :
33.120.20; 33.120.20
Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuse...
IEC 60269-2:2013+AMD1:2016 provides supplementary requirements for fuses for use by authorized persons and are generally designed to be used in installations where the fuse-links are accessible to, and may be replaced by, authorized persons only. Fuses for use by authorized persons according to the following fuse systems also comply with the requirements of the corresponding subclauses of IEC…
Éditeur :
IEC
Statut :
Publié
Date de publication :
2016-08-04
Code(s) de l'ICS :
29.120.50
Road vehicles — Local Interconnect Network (LIN) — Part 3: Protocol specification
ISO 17987-3:2016 specifies the LIN protocol including the signal management, frame transfer, schedule table handling, task behaviour and status management and LIN master and slave node. It contains also OSI layer 5 properties according to ISO 14229‑7 UDSonLIN-based node configuration and identification services (SID: B016 to B816) belonging to the core protocol specification. A node (normally a…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2016-08-04
Code(s) de l'ICS :
43.040.15
Microwave ovens
1.1 This Standard applies to microwave ovens capable of generating less than 25 kW of microwave power and intended to be used in nonhazardous locations in household and commercial applications, in accordance with Canadian Electrical Code, Part I (“CE Code”). 1.2 This Standard applies to microwave ovens intended to operate through the application of electromagnetic energy at frequencies within…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2016-07-31
Code(s) de l'ICS :
97.040.20
Explosive atmospheres — Part 35-1: Caplights for use in mines susceptible to firedamp — General requ...
This part of IEC 60079-35 specifies requirements for the construction, testing and marking of caplights, including caplights with a point of connection for other equipment, for use in mines susceptible to firedamp (Group I – electrical equipment for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition. The requirements for…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2016-07-31
Code(s) de l'ICS :
29.260.20
Explosive atmospheres — Part 35-2: Caplights for use in mines susceptible to firedamp — Performance ...
This part of IEC 60079-35 details those performance and other safety features of caplights, including those with a point of connection for another equipment, not covered in IEC 60079-35-1, but which are important for the safety and working conditions of the user. It may also be applied to caplights for use in mines not likely to be endangered by firedamp. NOTE When this part of the standard is…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2016-07-31
Code(s) de l'ICS :
29.260.20
Connecting components for personal fallarrest systems (PFAS)
1.1 This Standard specifies design and performance requirements, test methods, and requirements for marking and labelling individual connecting components used as part of a personal fall-arrest system (PFAS). This Standard applies to components that are a) used in the interconnection of a complete PFAS unit in accordance with the applicable CSA Z259 series of standards; b) intended to be…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2016-07-31
Code(s) de l'ICS :
13.340.99
Safety requirements for power electronic converter systems and equipment - Part 1: General
IEC 62477-1:2012+AMD1:2016 applies to Power Electronic Converter Systems (PECS) and equipment, their components for electronic power conversion and electronic power switching, including the means for their control, protection, monitoring and measurement, such as with the main purpose of converting electric power, with rated system voltages not exceeding 1 000 V a.c. or 1 500 V d.c. This document…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2016-07-27
Code(s) de l'ICS :
29.200