Standard for Cellulose Fibre Insulation (CFI) for Buildings
1. SCOPe
1.1
This Standard specifies requirements for treated wood-based cellulose
fibre intended for use as thermal insulation (cellulose fibre insulation, CFI)
in new and existing buildings within the temperature range of -60°C to 90°C.
1.2
This Standard describes general requirements for the material and
additional requirements specific to applications. The applications are…
1.1 Scope
1.1.1 Types of Regulators. This standard applies to individual gas appliance
pressure regulators, which are not a part of a combination control (see Part V,
Definitions), constructed entirely of new, unused parts and materials,
hereinafter referred to as regulators intended for application on individual
gas appliances.
This standard also applies to negative gas appliance…
1.1 Scope
1.1.1 This standard applies to newly produced combination gas controls (see
Definitions, Part IV), hereinafter referred to as controls, constructed
entirely of new, unused parts and materials.
1.1.2 The combination control may include other functions such as pilot gas
filters, pressure switches, etc., which shall be of an approved type (see
Definitions, Part IV), or shall…
B64.0-01
Definitions, General Requirements, and Test Methods for Vacuum Breakers and Backflow Preventers
1. Scope
1.1
Vacuum breakers and backflow preventers that are specified in the B64 Series of CSA Standards include only those devices that are designed for use in potable water supply systems to prevent cross-connections.
1.2
This Standard provides definitions, general…
This CSA Standard is a harminized Standard with ANSI Z21.72-2000.
1.1 SCOPE
1.1.1 This standard applies to portable type gas camp stoves, having input ratings of 12,000 Btu per hour (3.5 kW) or less per burner for use:
a. With propane, butane, liquefied petroleum gas and any combination thereof;
b. Outdoors only.
1.1.2 Stoves and components employing materials or having forms of…
Information technology — Telecommunications and information exchange between systems — 34-pole DTE/D...
This International Standard specifies the 34-
pole connector and the assignment of contact
numbers at the interface between data terminal
equipment (DTE) and data circuit-terminating
equipment (DCE) where ITU-T
Recommendation V.36 or Recommendation
X.21bis together with Recommendation V.10
and V.11 are applicable.
NOTE 1 An interoperation between interfaces
designed according to electrical…
Information technology - 8 mm wide magnetic tape cartridge for information interchange - Helical sca...
This International Standard specifies the physical and magnetic characteristics of an 8 mm wide magnetic tape cartridge
containing a memory chip to enable physical interchange of such cartridges between drives. It also specifies the quality of the
recorded signals, the recording method and the recorded format - called Advanced Intelligent Tape No. 1 with Memory In
Cartridge (AIT-1 with MIC) -…
Information technology - Telecommunications and information exchange between systems - 34-pole DTE/D...
This International Standard specifies the 34-
pole connector and the assignment of contact
numbers at the interface between data terminal
equipment (DTE) and data circuit-terminating
equipment (DCE) where ITU-T
Recommendation V.36 or Recommendation
X.21bis together with Recommendation V.10
and V.11 are applicable.
NOTE 1 An interoperation between interfaces
designed according to electrical…
Industrial automation systems and integration — Product data representation and exchange — Part 23: ...
This part of ISO 10303 specifies the implementation of the functional interface specified in the standard
data access interface (SDAI), ISO 10303-22, in the C++ programming language.
The following are within the scope of this part of ISO 10303:
— access to and manipulation of data types and entities which are specified in ISO 10303-22;
— convenience functions suitable to this language binding;
—…