Juniors, Misses and Women's Canada Standard Sizes Tricot Knit Full and Half
Slips - Dimensions
This standard applies to the dimensions considered essential to provide for the
fit of full (adjustable straps or built-up shoulders) and half slips made from
non-stretch fabrics i.e. tricot knit, that are intended for wear by juniors
(CSS Juniors' Range Sizes 5 to 19), misses (CSS Misses' Range Sizes 6 to 20)
and women (CSS Women's Range Sizes 30 to 48). Dimensions for longer…
Thermal Insulation, Block or Blanket, Elevated Temperature
1.1 This standard applies to three types of thermal insulating blocks and one
type of thermal insulating blanket for elevated temperature.
1.2 These insulating products are intended for use between the hot surfaces of
insulating fire bricks and the casings of boilers, where the temperature of the
hot surface is less than 1090 degrees Celsius.
This standard applies to two types and five classes of faced and unfaced
inorganic fibrous thermal insulation blankets for application on surfaces with
temperatures for a maximum up to 650 degrees C. Products to this standard may
include a surface covering that forms an integral part of the insulation.
This standard applies to rigid cellular glass thermal insulation for use on
surfaces having a temperature range of -270 to +425 degrees C in buildings, on
tanks, pipes, tubing and equipment (Note 1).
Note 1:
Materials covered by this standard may contain a controlled substance
under the Controlled Products Regulations (par. 2.1.2). For verification, where
applicable, the manufacturer…
1.1 This standard applies to a high-build vinyl coating suitable for use in
marine atmospheres including immersion in sea water.
1.2 For more detailed information on intended uses, see par. 7.2.
1.1 This standard applies to antifouling paint for use on steel over a system
comprising a vinyl pretreatment coating and a vinyl primer conforming to CGSb
standards 1-GP-121 and CAN/CGSB-1.122 respectively.
1.2 For more detailed information on intended uses, see par. 7.2.
Juniors, Misses and Women's Canada Standard Sizes Coats - Dimensions
This standard applies to the dimensions considered essential to provide for the
fit of "basic" coats, with double lining (not zip-out lining) for wear by
juniors (CSS Juniors' Range Sizes 5 to 19), misses (CSS Misses' Range Sizes 6
to 20), and women (CSS Women's Range Sizes 10-1/2 to 28-l/2 and 30 to 48).
Dimensions for shorter and longer waist lengths are included.
Electromechanical contactors for household and similar purposes
Applies to electromechanical air break contactors for household and similar purposes provided with main contacts intended to be connected to circuits the rated voltage of which does not exceed 440 V a.c. with rated operational currents less than or equal to 63 A for utilization category AC-7a and 32 A for utilization category AC-7b, and rated conditional short-circuit current less than or equal…
1.1 Scope
This Standard provides rules and requirements for the design and fabrication of
steel fixed offshore structures where the design is based on limit states.
1.2 Application
1.2.1
This Standard applies unconditionally to steel and steel/concrete composite
fixed offshore structures. Supplementary rules or requirements may be
necessary for unusual types of construction.…