Radio-frequency connectors. Part 20: R.F. coaxial connectors with inner diameter of outer conductor ...
Provides basic mating and performance information for a subminiature coaxial connector for use with flexible and semi-rigid r.f. cables. The connectors are usable up to a frequency of 6 GHz. Only the interface dimensions are standardized. Other technical data are supplied for guidance only.
Guide to voltage fluctuation limits for household appliances (relating to IEC Publication 60555-3)
IEC 60555-3 specifies limits for the voltage fluctuations that may be produced by an individual appliance and gives methods of test and calculation. The purpose of this report is to explain the way in which the limits and test methods were developed so as to help understanding of the standard and the way in which it should be used. After reviewing the need for voltage fluctuation limits, the…
Describes instruments for the measurement of frequency weighted and time averaged sound-pressure levels. Ensures specified accuracy and stability of an integrating sound level meter and reduces to the practical minimum any differences in equivalent measurements taken with instruments of various makes and models which satisfy the requirements of this standard. Specifies the following…
Industrial-process control valves. Part 6: Mounting details for attachment of positioners to control...
Permits a variety of positioning devices which respond to a linear motion to be mounted on the actuator of a control valve, either directly or by employing an intermediate mounting bracket.
The standardized mounting applies to positioners which are mounted on the side of the actuator, to those actuators which have a travel of 100 mm or less, and is designed to cover three basic types of actuator…
1. Scope
1.1 This Standard applies to cord-connected electric clocks intended for use in household and other nonhazardous indoor dry locations in accordance with the Rules of the Canadian Electrical Code, Part I, and having a rating not exceeding 125 V ac and 30 W input and secondary circuits not exceeding 240 V.
1.2 This Standard includes both motor and electronically driven, di…
Applies to the design, based on limit states, of structural
members cold formed to shape from carbon or low alloy steel
sheet, strip or plate up to 25 mm in thickness and intended for
load carrying purposes in buildings. For application of this
Standard to the design of cold formed steel structural members in
structures other than buildings, supplementary specifications
shall be provided…
Specifies minimum performance requirements and test procedures to
asses compliance to those requirements, for hemodialysers,
hemofilters and hemoconcentrators used for kidney dialysis and
associated procedures. The Standard includes requirements for
hemodialysers of coil, hollow fibre and parallel, plate design.
It does not apply to the extracorporeal circuit, plasma filters,
hemoperfusion…
Extracorporeal Circuits for Use with a Hemodialyser, Hemofilter, or
Hemoconcentrator
Specifies minimum performance requirements and test procedures to
assess compliance to those requirements, for the extracorporeal
circuit for use with hemodialysers, hemofilter or
hemoconcentrators used for kidney dialysis and associated
procedures. This Standard applies to blood tubings and accessory
tubings for the extracorporeal circuit. Accessory tubings include
fluid infusion tubing…
Electrically Heated Bedding Appliances for Household Use
1. Scope
1.1 This Standard applies to cord-connected, electrically heated bedding such as blankets, comforters, quilts, sheets, mattresses, and mattress pads with associated control units, for household use, designed for nominal 120 V ac circuits and to be used in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2 This Standard does not apply…