Arc welding equipment — Part 7: Torches Matériel de soudage à l’arc — Partie 7 : Torches
1 Scope
This part of IEC 60974 specifies safety and construction requirements for TORCHES used for
arc welding and allied processes. This document is applicable to MANUAL, MECHANICALLY
GUIDED, AIR-COOLED, LIQUID-COOLED, MOTORIZED, SPOOL-ON and FUME EXTRACTION TORCHES.
In this document, a TORCH consists of the TORCH BODY, the CABLE-HOSE ASSEMBLY and other
components.
This document is also…
Electromagnetic compatibility (EMC) — Part 4-11: Testing and measurement techniques — Voltage dips, ...
1 Scope
This part of IEC 61000 defines the immunity test methods and range of preferred test levels
for electrical and electronic equipment connected to low-voltage power supply networks for
voltage dips, short interruptions, and voltage variations.
This document applies to electrical and electronic equipment having a rated input current not
exceeding 16 A per phase, for connection to 50 Hz…
Engins antidéflagrants hors-rails à moteur diesel, pour utilisation dans les mines souterraines gris...
1 Domaine d’application
1.1 Inclusions
Cette norme décrit les exigences relatives à la construction et à la mise à l’essai des engins autopropulseurs hors-rails à moteur diesel, pour utilisation dans les mines souterraines grisouteuses, neufs. Elle s’ajoute aux normes CSA M424.0 et CSA M424.2 ou les modifie.
Note : L’environnement de travail des mines grisouteuses est caractérisé par la…
Data qualification for Canadian automated hydrometeorological monitoring stations
1 Scope
1.1
This Standard provides a framework to assess, tabulate, and quantify factors contributing to the quality of hydrometeorological data. It includes a description of the data quality rating system, a description of organization-wide factors linked to management systems, training and certification of operators, as well as data storage and archiving policies, and a description of…
Safe installation and operation of haemodialysis and peritoneal dialysis in a home setting
1 Scope
1.1 Inclusions
This Standard specifies requirements for the safe installation and operation of haemodialysis and peritoneal dialysis performed in a home setting. It is intended for use by dialysis providers, including health care workers and professionals who perform technical and operational functions associated with home dialysis, as well as stakeholders who have an interest in safety…
1 Scope
1.1 General
This Standard specifies requirements for the identification of hazards, and assessment and control of risks, across first responder occupations. This Standard can be applied to any type of risk and can be applied to both sleep-related and task-related fatigue.
It is intended that this Standard be utilized to harmonize risk management processes in existing and future…
1 Scope
1.1 Application
This Standard provides minimum requirements for oil-burning equipment, including
a)
fuel oil filters;
b)
draft regulators;
c)
flue pipe mounted heat reclaimers;
d)
through-the-wall venting systems;
e)
systems that supply outside combustion air; and
f)
used-oil-burning equipment.
1.2 Intended use
This Standard is to be used in conjunction with the other…
1 Scope
1.1 Application
This Standard applies to
a) oil burners of the atomizing type (irrespective of size, firing rate, or grade* of fuel oil) that are
designed primarily for installation in warm-air, hot-water, and steam-heating equipment;
* The grade of fuel oil should be as specified in CSA B140.0, except for grade B6-B20, which is specified in
ASTM D396.
b) atomizing-type oil burners…
1 Scope
1.1 Application
This Standard applies to complete, vent- (flue-) connected, or direct vent connected oil-fired warm air furnaces and unit heaters, irrespective of the heating capacity or the type of burner used. This Standard also applies to oil-fired condensing warm air furnaces.
1.2 Intent
This Standard applies to furnaces employing forced circulation of the heated air and furnaces…
1 Scope
1.1 Application
This Standard applies to
a)
complete vent (flue) -connected or direct-vent connected, oil-fired steam, and hot-water boilers that are provided with automatic control devices;
b)
oil-fired steam and hot-water condensing boilers;
c)
boilers having an input of less than 117.2 kW (400 000 Btu/h);
d)
low-pressure boilers (as defined in Clause 3) having an input of 117…