General Requirements for Concrete Containment Structures for CANDU Nuclear Power Plants
1.1
This Standard provides the general requirements used in the design,
construction, testing, and commissioning of concrete containment structures for
CANDU nuclear power plants designated as class containment and is directed to
the owners, designers, manufacturers, fabricators, and constructors of the
concrete components and parts.
Note: The requirements of the N287 Series of CSA Standards…
Rigid Reinforced Thermoset (RE) Conduit and Associated Fittings
1. Scope
1.1
This Standard applies to rigid reinforced, nonhaloginated, thermoset material
(RE) conduit, bends, and accessories for installation and use in accordance
with the Rules of the Canadian Electrical Code, Part I, for nonhazardous
locations.
1.2
The products covered by this Standard are intended for use at a maximum
continuous operating temperature of 110°C.
1.3
This…
1.1
This Standard covers the minimum design, construction, operation, abandonment,
and safety aspects of hydrocarbon storage in underground formations and
associated equipment. Equipment shall include all subsurface process
equipment, the wellhead, and all safety equipment related to the storage
facilities, wells, and wellheads. Hydrocarbons shall include crude oil,
diesel, natural gas,…
Examination and Testing Requirements for Concrete Containment Structures for CANDU Nuclear Power Pla...
1. Scope
1.1 This Standard provides the examination and testing requirements that will apply to the work of any organization participating in the construction, installation, and fabrication of parts or components of concrete containment structures, or both, that are defined as class containment.
Energy Efficiency Test Methods for Three-Phase Induction Motors
1.1
This Standard specifies the test methods to be used in measuring the energy
efficiency of three-phase induction motors in support of a consumer/user
information program. The method of determining and marking the nominal
efficiency values are also specified.
1.2
This Standard applies to three-phase induction motors rated 0.746 kW at 1800
r/min (or equivalent*) and greater.
*An…
1.1 SCOPe
1.1.1 This standard applies to automatically operating gas-fired central
furnaces (see Part XI, Definitions), hereinafter referred to as furnaces, for
installation in residential, commercial, and industrial structures including
furnaces for Direct Vent, Recreational Vehicle, Outdoor, and Manufactured
(Mobile) Homes.
These furnaces may include a cooling unit. All units shall…
Canada Standard Children's Sizes 2 to 6X, Girls' Sizes 7 to 16 and Boys'
Sizes 7 to ...
This standard applies to the dimensions considered essential to provide for the
fit of housecoats and robes having either a tie closure or a button closure
that are intended for wear by little girls and little boys (CSS Regular Range,
sizes 2 to 6X), girls (CSS Regular Range, sizes 7 to 16) and boys (CSS Regular
Range, sizes 7 to 20).
Infants' Canada Standard Sizes Blanket and One-Piece Sleepers - Dimensions
This standard applies to the dimensions considered essential to provide for the
fit of blanket sleepers made from non-stretch fabrics and of knitted one-piece
sleepers made from stretch fabrics for wear by infants wearing diapers.
Sleepers that stretch in both horizontal and length directions of the garment
are not excluded provided they meet the horizontal stretch requirements.
1.1
This standard covers the general requirements common to all
fibreglass-reinforced plastic (FRP) products intended for use in corrosive
industrial applications. These general requirements outline the minimum
acceptable parameters for materials, laminates, design, fabrication, and
inspection (Note 1).
1.2
It is the responsibility of the user to determine whether the intended
application of…