Fenestration energy performance/User Guide to CSA A440.2:22, Fenestration energy performance
1 Scope
1.1 General
This Standard applies to
a)
fenestration systems covered by AAMA/WDMA/CSA 101/I.S.2/A440, including
i)
vertically sliding windows;
ii)
horizontally sliding windows;
iii)
dual-action windows;
iv)
casement windows, both fixed and operable;
v)
projecting (awning/hopper) windows;
vi)
fixed windows;
vii)
sidelites;
viii)
transom windows;
ix)
sliding doors;
x…
Methods of testing petroleum and associated products - Low temperature flow test (LTFT) for diesel f...
1.1 This method describes a procedure for determining the filter plugging tendency of diesel fuels at low
temperature, usually due to the formation of wax crystals (see note in 6.1).
1.2 The method applies to all distillate diesel fuels. Fuels are expected to provide satisfactory fuel flow in
automotive equipment at temperatures equal to or higher than the minimum pass temperature as described…
CanadaMéthodes d’essai des produits pétroliers et produits connexes – Essai d’écoulement à basse tem...
1.1 La présente méthode permet de déterminer la tendance des combustibles diesels à colmater les filtres à
basse température généralement en raison de la formation de cristaux de cire (voir la note en 6.1).
1.2 La méthode s’applique à tous les combustibles diesels distillés. Il est prévu que les combustibles s’écouleront
librement dans le matériel automobile à des températures égales ou…
Non-destructive testing — Qualification and certification of NDT personnel (ISO 9712:2021, IDT)
This document specifies requirements for the qualification and certification of personnel who perform industrial non-destructive testing (NDT) in the following methods.
a) acoustic emission testing;
b) eddy current testing;
c) leak testing (hydraulic pressure tests excluded);
d) magnetic testing;
e) penetrant testing;
f) radiographic testing;
g) strain gauge testing;
h) thermographic…
1 Scope
1.1 This Standard covers plastic plumbing fixtures and specifies requirements for materials,
construction, performance, testing, and markings.
1.2 This Standard covers the following plumbing fixtures:
(a) bathtubs and combination tub/showers;
(b) lavatories;
(c) shower bases and shower stalls;
(d) sinks:
(i) bar sinks;
(ii) kitchen sinks;
(iii) laundry sinks;
(e) service sinks…
1 Scope
1.1
This Standard applies to free-standing poles of ferrous metal, aluminum, polymeric, concrete, fibre- reinforced structures, and wood, and to their accessories, for use in the support of lighting equipment having ratings of 600 V and less, and intended to be installed in the commercial and industrial nonhazardous locations in accordance with the Rules of the Canadian Electrical Code…
1 Scope
1.1 This Standard applies to low-voltage fuses rated 1000 V or less, AC and/or DC, with interrupting
ratings up to 300 kA (200 kA for Mexico). These fuses are intended to be used in accordance with the
Canadian Electrical Code, Part I, CSA C22.1, NOM – 001, Mexican Electrical Code, and the National
Electrical Code, NFPA 70.
1.2 This Standard and its subsequent Parts establish the…
Explosive atmospheres — Part 26: Equipment with separation elements or combined levels of protection...
1 Scope
This part of IEC 60079 specifies requirements for construction, testing and marking for Ex
Equipment that contains parts of the equipment with different Equipment Protection Levels
(EPLs) and a separation element. This equipment is mounted across a boundary where different
EPLs are required, for example between different gas hazardous areas, dust hazardous areas
or gas hazardous…
Test method, marking requirements, and energy efficiency levels for three-phase induction motors
1 Scope
1.1 Application
This Standard specifies a test method for three-phase induction motors rated 0.746 kW and higher. The Standard also references energy efficiency levels for three-phase induction motors rated 0.746 kW up to 400 kW.
This Standard references energy efficiency levels for both NEMA and IEC motor designations. Efficiency requirements for units rated for operation at 60 Hz are…
1 Scope
1.1 Inclusions
This Standard specifies the test methods to be used in measuring the energy efficiency of small direct- current (dc), and single- and small three-phase alternating-current (ac) motors. It includes the following motor types:
a)
capacitor, permanent-split;
b)
capacitor, capacitor-start or capacitor-run;
c)
split phase;
d)
split phase start, capacitor-run;
e)…