Preface
This is the first edition of CSA Special Publication PLUS 9014, ISO 9000 Interpretations. It is a compendium of interpretations given on the ISO 9000 family of Standards and approved by the CSA Technical Committee on Quality Management (TC on QM).
The ISO 9000 family of Standards was developed by quality experts from around the world, under the auspices of the Internationa l…
Standard for Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium
Density, Material -...
1. SCOPe
1.1 This Standard specifies the requirements and test methods for
spray-applied rigid polyurethane cellular plastics used as thermal insulation
in buildings and other applications, when applied either "on site" or in a
manufacturing facility.
1.2 The spray-applied rigid polyurethane cellular plastic thermal insulation
shall not be used when the continuous service…
Standard for Thermal Insulation - Spray Applied Rigid Polyurethane Foam, Medium
Density, Installer&...
1. Scope
1.1 This standard provides procedures to installers of spray-applied rigid
polyurethane cellular plastic used as thermal insulation in building
construction and other applications, whether applied either "on site" or in a
manufacturing facility.
1.2 The procedures include selection of chemical components, application,
quality control and documentation of the…
Gas Water Heaters
Volume IIi
Storage Water Heaters, With Input Ratings Above 75,000 Btu Per Hour,
...
1.1 SCOPE
1.1.1 This standard applies to newly produced, large automatic storage water
heaters having input ratings above 75,000 Btu per hour (21 980 W),
instantaneous water heaters and circulating water heaters (see Part IV,
Definitions), hereinafter referred to as water heaters or appliances,
constructed entirely of new, unused parts and materials…
1.1 SCOPe
1.1.1 This standard applies to newly produced pool heaters (see Part IV,
Definitions), hereinafter referred to as pool heaters or appliances,
constructed entirely of new, unused parts and materials, for heating
nonpotable water stored at atmospheric pressure, such as water in
swimming pools, spas, hot tubs and similar applications:
a…
1. SCOPE
1.1 This standard applies to automotive fuel methanol (M85) that contains 15%
unleaded gasoline. It is intended for use in automotive engines under a wide
range of climatic conditions.
1.2 The fuel methanol shall only be used in equipment specifically designed
for its use. Some fuel systems may not be fully compatible with fuel produced