Site preparation, foundation, and installation of buildings
1 Scope
1.1 Application
This Standard applies to single- and multi-section buildings supported on longitudinal floor beams, or perimeter rim joists designed to perform as beams.
1.2 Issues addressed
This Standard specifies requirements for the following aspects of building installation:
a)
site preparation;
b)
permanent foundations;
c)
anchorage to resist overturning and pier toppling…
Contrôle, inspection et surveillance de l’érosion et des sédiments
1 Domaine d’application
1.1 Généralités
Cette norme précise les exigences minimales pour l’inspection des mesures de CÉS tout au long d’un projet de construction, ainsi que les exigences et les recommandations pour la surveillance de certains paramètres de qualité de l’eau. Elle comprend également une description des qualifications requises pour un inspecteur qualifié du contrôle de l’érosion…
1 Scope
1.1 General
This Standard covers bird-friendly building design in both new construction and existing buildings and is intended to reduce bird collisions with buildings. The Standard provides bird-friendly design requirements for glazing, building-integrated structures, and overall building and site design.
1.2 Exclusions
This Standard considers design aspects of glazing, buildings…
Explosive atmospheres — Part 13: Equipment protection by pressurized room “p” and artificially venti...
This part of IEC 60079 gives requirements for the design, construction, assessment,
verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere (an area
normally requiring an equipment protection level (EPL) Gb, Gc, Db or Dc) without an
internal source of gas/vapour release and protected by pressurization…
Lifts for the transport of persons and goods — Part 3: Requirements from other Standards (ASME A17.1...
1.1 This document specifies the safety rules for permanently installed new passenger or goods passenger lifts, with traction, positive or hydraulic drive, serving defined landing levels, having a car designed for the transportation of persons or persons and goods, suspended by ropes, chains or jacks and moving between guide rails inclined not more than 15° to the vertical.
1.2 This document…
1 Scope
1.1 This Standard sets forth methods for both new installation and replacement installation of factory assembled windows, exterior doors, and skylights that are intended for installation in low-rise buildings and buildings used primarily for, but not limited to, residential occupancy where the windows, doors, and skylights (including window wall) are R, LC, or CW class within the…
Photometric performance of roadway and street lighting luminaires
1 Scope
1.1
This Standard specifies photometric performance requirements for luminaires that are used for roadway and street lighting applications as a function of unit power density (UPD).
1.2
The following light sources are addressed in this Standard:
a)
clear HPS lamp
b)
clear metal halide lamp and
c)
LED.
1.3
This Standard is based on
a)
average luminance, luminance uniformity…
Power installations exceeding 1 kV a.c. — Part 1: Common rules Installations électriques en courant...
1 Scope
This Standard applies to indoor substations, generating stations, and fenced outdoor supply stations and
substations (including supply substations on customer premises).
For the purpose of interpreting this Standard, an electrical power installation is considered to be one of
the following:
a) a substation, i.e., a closed electrical operating area in a transmission or distribution…
Erosion and sediment control inspection and monitoring
1 Scope
1.1 General
This Standard specifies minimum requirements for the inspection of ESC measures throughout the duration of a construction project, as well as requirements and recommendations for monitoring certain water quality parameters. It also includes a description of the required qualifications for a qualified erosion and sediment control inspector (QESCI) and a QESCI in-training (…
Antennas, towers, and antenna supporting structures
1 Scope
1.1 General
This Standard applies to structural antennas, towers, antenna-supporting structures, and roof- and wall- mounted structures, including their components, such as guys and foundations. It covers the structural design, fabrication, and erection of new structures and the modification of existing structures.
1.2 Exclusions
This Standard is not intended to apply to
a)…