Installation code for decentralized wastewater systems
Scope
1.1
1.1.1
This Code covers decentralized wastewater systems that use soil absorption systems for infiltration, dispersal, and final treatment of wastewater and serve residential, institutional, and commercial establishments.
Note: In this Code, the term "system" refers to a decentralized wastewater system.
1.1.2
This Code also covers sewage holding tanks.
Note: Holding…
1 Scope
1.1 These requirements cover single pole locking-type separable attachment plugs, cord connectors,
panel inlets, and panel outlets, adapters, and accessories, rated up to a maximum of 800 amperes and
up to 600 volts ac or dc and not intended for connection or disconnection under load conditions.
1.2 These devices are intended to provide power from feeders or branch circuits, or…
Medical electrical equipment — Part 2-56: Particular requirements for basic safety and essentialperf...
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of a CLINICAL
THERMOMETER in combination with its ACCESSORIES, hereafter referred to as ME EQUIPMENT. This standard specifies the general and technical requirements for electrical CLINICAL THERMOMETERS. This standard applies to all electrical CLINICAL THERMOMETERS that are used for…
Appareils électromédicaux — Partie 2-56 : Exigences particulières relatives à la sécurité fondamenta...
201.1.1 Domaine d'application
Remplacement:
La présente Norme internationale s'applique à la SÉCURITÉ DE BASE et aux PERFORMANCES ESSENTIELLES d'un THERMOMÈTRE MÉDICAL en combinaison avec ses ACCESSOIRES, désigné ci-après APPAREIL EM. La présente norme spécifie les exigences générales et techniques relatives aux THERMOMÈTRES MÉDICAUX électriques. La présente norme s'…
1 Scope
1.1
This Standard specifies performance, design, testing, marking, classification, and other requirements
related to anchorage connectors in travel restraint, fall arrest, work positioning, and suspended
component/tie-back line systems.
1.2
The requirements of this Standard include (where applicable) anchorage connectors attached to an
anchorage. Methods of verifying the actual strength…
1 Scope
1.1 General
This Standard specifies requirements for workplace electrical safety necessary for the practical safeguarding
of workers during activities such as the installation, inspection, operation, maintenance, and demolition of
electric conductors and electric equipment, as well as work in proximity of energized electrical equipment.
1.2 Application
While it can be applied by…
1 Scope
1.1
This Standard specifies a set of technical requirements and test methods for glazed and unglazed liquid
heating solar collectors and covers operating performance and marking requirements.
1.2
This Standard applies to glazed and unglazed liquid heating solar collectors used for converting solar
radiation into thermal energy by heating a liquid flowing through the collector.…
Guideline for the exemption or clearance from regulatory control of materials that contain, or poten...
1 Scope
1.1
This Guideline provides direction for the application of exemption quantity and clearance level criteria
for the release of materials containing, or potentially containing, radioactive nuclear substances, and the
activities necessary to demonstrate compliance with these criteria. Specifically, this Guideline addresses
clearance of materials that are regulated by the Nuclear…
Medical electrical equipment — Part 2-1: Particular requirements for thebasic safety and essential p...
201.1 Scope, object and related standards
Clause 1 of the general standard1) applies, except as follows:
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to
50 MeV, used for treatment of PATIENTS.
This particular standard, with the…