Thermal insulation products — Conformity control systems — Part 2: In-situ products
ISO 12576-2:2008 establishes three systems for the conformity control of thermal insulating products that are manufactured on-site from components produced in a factory and provides the minimum requirements for each system. Examples of these types of products are loose fill and spray-applied insulations.
The purpose of ISO 12576-2:2008 is to provide uniform methods to determine whether the…
Entreposage à sec provisoire du combustible irradié
1 Domaine d'application
1.1
Cette norme s'applique aux systèmes d'entreposage à sec provisoire du combustible irradié.
1.2
Cette norme établit des exigences visant le choix des emplacements, la conception, la construction, la mise en service, l'exploitation et le déclassement des systèmes d'entreposage à sec. Les systèmes d'entreposage à sec comprennent toutes les…
Recommendations for small renewable energy and hybrid systems for rural electrification - Part 7-3: ...
IEC/TS 62257-7-3:2008(E) specifies the general requirements for the selection, sizing, erection and operation of generator sets in decentralized rural electrification systems. Applies to all low voltage combustion engine electricity generator sets with a rated power up to 100 kVA, and designed for supplying electrical power to isolated sites used in systems as described in IEC/TS 62257-2.
Moteurs alternatifs à combustion interne — Mesurage des émissions de gaz d'échappement — Partie...
L'ISO 8178-2:2008, conjointement avec l'ISO 8178-1 et l'ISO 8178-11, spécifie les méthodes de mesure et d'évaluation sur site des émissions de gaz et de particules des gaz d'échappement des moteurs alternatifs à combustion interne dans des conditions stabilisées et en régime transitoire.
L'ISO 8178-2:2008 est applicable lorsque les moteurs utilisés dans des véhicules…
Reciprocating internal combustion engines — Exhaust emission measurement — Part 2: Measurement of ga...
ISO 8178-2:2008, together with ISO 8178-1 and ISO 8178-11, specifies the measurement and evaluation methods for gaseous and particulate exhaust emission from reciprocating internal combustion engines (RIC engines) under steady-state and transient conditions for field testing.
ISO 8178-2:2008 is applied when RIC engines used in off-road vehicles, marine installations, generating sets, diesel rail…
Safety of laser products - Part 3: Guidance for laser displays and shows
This part of IEC 60825, which is a technical report, gives guidance on the planning and design, set-up and conduct of laser displays and shows that make use of high power lasers. The laser power needed to produce effective theatrical or artistic displays in large spaces such as theatres, arenas, or architectural sites is great enough to pose a severe accidental exposure hazard, even when personal…
Petroleum and natural gas industries — Field testing of drilling fluids — Part 1: Water-based fluids
ISO 10414-1:2008 provides standard procedures for determining the following characteristics of water-based drilling fluids: drilling fluid density (mud weight), viscosity and gel strength, filtration, water, oil and solids contents, sand content, methylene blue capacity, pH, alkalinity and lime content, chloride content and total hardness as calcium.
ISO 10414-1:2008 provides additional test…
Site Preparation, Foundation, and Anchorage of Manufactured Homes
1 Scope
1.1
This Standard applies to manufactured and modular homes designed to be supported on longitudinal floor beams.
Note: For simplicity, the term "manufactured home" is used in this Standard to refer to both manufactured homes and modular homes.
1.2
This Standard includes requirements for the following aspects of manufactured home installation:
(a) site preparation;
(b)…
Management of Low- and Intermediate-Level Radioactive Waste
1 Scope
1.1
This Standard specifies requirements for the management of low- and intermediate-level radioactive waste in solid, liquid, or gaseous states.
1.2
This Standard applies to organizations and facilities that generate, possess, manage, and transport lowand intermediate-level radioactive waste, including power reactors, research institutes, laboratories, and industrial facilities…