Guideline for Seismic Risk Reduction of Operational and Functional Components (OFCs) of Buildings
1. Scope
1.1 General
This Guideline provides information and methodology to identify and evaluate hazards caused by earthquake forces acting on operational and functional components (OFCs) and to undertake appropriate mitigation strategies and techniques. It is important to note that seismic risk reduction of OFCs is affected by the structural performance of the building, although the…
1 Scope
1.1
This Standard addresses issues related to the safety of human perfusable organs used for transplantation purposes. It includes aspects of safety for potential and actual donors and recipients, personnel, and others who may be exposed to, or affected by, the transplant of perfusable organs.
1.2
This Standard applies to establishments (or facilities) and individuals involved in the…
Electromagnetic Compatibility (EMC) - Part 4: Testing and Measurement Techniques - Section 5: Surge ...
This National Standard of Canada is equivaent to International Standard CEI/IEC 1000-4-5: 1995 (first edition, 1995-02).
This section of IEC 1000-4 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to…
Règles de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Partie ...
La présente norme nationale du Canada est basée sur la norme internationale CEI 1010-2-010:1992.
1. Domaine d'application et objet
Cet article de la partie 1 est applicable, à l'exception des cas suivants:
1.1 Domaine d'application
Cette partie 2 s'applique uniquement aux appareils de laboratorie à alimentation électrique pour l'échauffement des…
Information technology - Open Systems Interconnection - Conformance testing
methodology and framewo...
The international community has decided to make this standard available only in
the English language version. It has been adopted as a National Standard of
Canada on this basis.
This National Standard of Canada is equivalent to International Standard
ISO/IEC 9646-1:1994.
1 Scope
1.1 ISO/IEC 9646 is a multi-part International Standard which specifies a
general methodology for…
Electromagnetic Compatibility (EMC) - Part 4-5: Testing and Measurement Techniques - Surge Immunity ...
This National Standard of Canada is equivalent to International Standard IEC 61000-4-5:2005.
1 Scope and object
This part of IEC 61000 relates to the immunity requirements, test methods, and range of recommended test levels for equipment to unidirectional surges caused by overvoltages from switching and lightning transients. Several test levels are defined which relate to different environment…
Information Technology - Portable Operating System Interface (POSIX) - Test Methods for Measuring Co...
This National Standard of Canada is equivalent to International Standard ISO/IEC 14515-1:2000/IEEE 2003.1, 1992 (first edition, 2000-12-15).
1.1 Scope
This standard defines the general requirements and test methods for measuring conformance to ISO/IEC 9945-1 :1990 (IEEE Std 1003.1-1990) hereinafter referred to as .POSIX.1. {3}.1 It also defines the test assertions for measuring conformance…
Scope
O80.0-1.1
This Standard sets forth requirements for materials, analysis of materials, and operational practices for pressure and thermal impregnation for the chemical preservation of wood.
1.2
The recommendations made in this Standard are based solely on the efficacy of the preservative in any specific application. As preservatives and their uses are regulated by government…
Environmental DNA (eDNA) reporting requirements and terminology
1 Scope
1.1 General
This Standard applies to the reporting of information regarding the conducting of eDNA biological surveys or assessments.
This Standard provides
a)
definitions for terms that are routinely used in the description of eDNA studies; and
b)
minimum reporting requirements for eDNA studies in a quality assurance/quality control context, including the following:
i)