Molecular in vitro diagnostic examinations — Specifications for pre-examination processes for formal...
1 Scope
This document specifies requirements and gives recommendations for the collection, handling, documentation, transport, storage and processing during the pre-examination phase of formalin-fixed and paraffin-embedded (FFPE) tissue specimens intended for qualitative and/or (semi-)quantitative in situ examination of the morphology and of biomolecules, such as metabolites, proteins, DNA and/…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1.1 Scope
Replacement:
This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES.
This group safety publication is primarily intended to be used as a product safety standard for
the products mentioned in the scope, but shall also be used by technical committees in the
preparation of its publications for products similar to those mentioned in the scope of this
standard, in…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1 Scope
1.1.1 Equipment included in scope
Replacement:
Replace the text, except the first paragraph, with the following new text:
This part of IEC 61010 applies to electrically powered laboratory atomic spectrometers with
thermal atomization.
NOTE 1 Examples include atomic absorption spectrometers, emission flame…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
This National Standard of Canada is equivalent to International Standard CEI/IEC 1010-2-061:1995.
1 Scope and object
This clause of part 1 is applicable except as follows:
1.1 Scope
Replacement:
Replace the complete text by the following:
This International Standard applies to electrically powered laboratory atomic
spectrometers with thermal atomization.
NOTE -…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1.1 Scope
1.1.1 Equipment included in scope
[Add the following paragraph]
This Standard covers equipment that is intended to be installed or used in accordance with CSA C22.1,
Canadian Electrical Code, Part I.
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
This Standard covers equipment intended to be installed or used in accordance with CSA C22.1, Canadian Electrical Code, Part I.
Cette norme vise l’appareillage destiné à être installé ou utilisé conformément à la CSA C22.1, Code canadien de l’électricité, Première partie.
Information technology — Implementation and operation of customer premises cabling — Part 4: Measure...
1 Scope
This part of ISO/IEC 14763 specifies the measurement at frequencies of E2E links of two- and
four-pair balanced cabling of 100 MHz of Class D and 250 MHz of Class E including free
connectors which terminate two and four pairs in both field and laboratory conditions.
The specifications for E2E links are described in ISO/IEC TR 11801-9902.
This document specifies laboratory and field…
This National Standard of Canada is equivalent to International Standard ISO 5007:2003 (second edition, 2003-03-15).
1 Scope
This International Standard specifies, in accordance with ISO 10326-1, a laboratory method for measuring and evaluating the effectiveness of the suspension of operator seats on agricultural wheeled tractors. It also specifies acceptance criteria based on the test results…
Safety requirements for electrical equipment for measurement, control, and laboratory use — Part 2-0...
1 Scope and object
This clause of Part 1 is applicable, except as follows:
1.1.1 Equipment included in the scope
Replacement:
Replace the first paragraph by the following:
This group safety publication is primarily intended to be used as a product safety standard for
the products mentioned in the scope, but shall also be used by technical committees in the
preparation of their publications…
Solid biofuels — Determination of water sorption and its effect on durability of thermally treated b...
1 Scope
This document specifies a method for the determination of water sorption in a laboratory setting and provides a measure for how the durability is impacted as a result of immersion in water. Post-immersion durability reduction is calculated as the difference between the durability of the as-received sample and the durability of the wetted product.