1 Scope
1.1 Introduction
1.1.1 Fire fighters (FF) performing operations involving buildings with attached or integrated Photovoltaic
(PV) arrays may be exposed to electrical hazards from damaged PV equipment. These requirements
provide a means for evaluation of PV Hazard Control components, equipment and systems that provide a
reduced level of shock hazard from energized PV system equipment…
Electrical insulation systems - Thermal evaluation of modifications to an established electrical ins...
IEC TR 61858-3:2020(E) provides information on the identification of electrical insulating materials and auxiliary components for the assessment of modifications to an established insulation system and gives guidance on the selection of feasible test procedures.
Material declaration for products of and for the electrotechnical industry
IEC 62474:2018+A1:2020 specifies the procedure, content, and form relating to material declarations for products of companies operating in and supplying the electrotechnical industry. Process chemicals and emissions during product use are not in the scope of this International Standard. It provides data to downstream manufacturers that:
- allows them to assess products against substance…
Déclaration de matières pour des produits de et pour l'industrie électrotechnique
L'IEC 62474:2018+A1:2020 décrit la procédure, le contenu et la forme des déclarations de matières pour les produits des entreprises et des fournisseurs de l'industrie électrotechnique. Les produits chimiques et les émissions du processus pendant l'utilisation du produit n'entrent pas dans le domaine d'application de la présente Norme internationale. Elle fournit aux…
Household electric direct-acting room heaters - Methods for measuring performance - Part 2: Addition...
IEC 60675-2:2020 applies to electric direct-acting room heaters.
This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiant factor for the information of users.
This document is used to measure the radiant factor of direct-acting room heaters.
This International Standard is to be used in conjunction with IEC 60675:1994, IEC…
Appareils électrodomestiques de chauffage des locaux à action directe - Méthodes de mesure de l'...
L'IEC 60675-2:2020 s’applique aux appareils électriques de chauffage des locaux à action directe.
Il définit les caractéristiques d'aptitude à la fonction associées à l'effet rayonnant et spécifie les méthodes de mesure du coefficient de rayonnement à titre d'information pour les utilisateurs.
Le présent document est utilisé pour mesurer le coefficient de rayonnement des…
Household electric direct-acting room heaters - Methods for measuring performance - Part 3: Addition...
IEC 60675-3:2020 applies to electric direct-acting room heaters.
This document defines performance characteristics related to the radiant effect and specifies methods for measuring the radiation efficiency for the information of users.
This document is used to measure the radiation efficiency of direct-acting room heaters.
This International Standard is to be used in conjunction with IEC 60675…