Software and systems engineering — Software testing — Part 2: Test processes
1 Scope
This document specifies test processes that can be used to govern, manage and implement software
testing for any organization, project or testing activity. It comprises generic test process descriptions
that define the software testing processes. Supporting informative diagrams describing the processes
are also provided.
This document is applicable to testing in all software…
Fenestration energy performance/User Guide to CSA A440.2:22, Fenestration energy performance
1 Scope
1.1 General
This Standard applies to
a)
fenestration systems covered by AAMA/WDMA/CSA 101/I.S.2/A440, including
i)
vertically sliding windows;
ii)
horizontally sliding windows;
iii)
dual-action windows;
iv)
casement windows, both fixed and operable;
v)
projecting (awning/hopper) windows;
vi)
fixed windows;
vii)
sidelites;
viii)
transom windows;
ix)
sliding doors;
x…
1 Scope
1.1 This Standard covers plastic plumbing fixtures and specifies requirements for materials,
construction, performance, testing, and markings.
1.2 This Standard covers the following plumbing fixtures:
(a) bathtubs and combination tub/showers;
(b) lavatories;
(c) shower bases and shower stalls;
(d) sinks:
(i) bar sinks;
(ii) kitchen sinks;
(iii) laundry sinks;
(e) service sinks…
Brûleurs à mazout à pulvérisation et à vaporisation
1 Domaine d’application
1.1 Application
Cette norme vise :
a)
les brûleurs à mazout à pulvérisation (peu importe les dimensions, le taux d’allumage ou la qualité* du mazout) conçus principalement pour être installés dans des appareils à air chaud, à eau chaude et à vapeur;
* La qualité du mazout devrait être conforme à CSA B140.0, à l’exception de la qualité B6-B20, qui est décrite dans ASTM…
1 Domaine d’application
1.1 Application
Cette norme s’applique aux générateurs d’air chaud et aux aérothermes alimentés au mazout, complets et raccordés à un conduit d’évacuation (carneau) ou à ventilation directe, quelque soit la puissance calorifique ou le type de brûleur utilisé. Cette norme s’applique également aux générateurs d’air chaud à condensation alimentés au mazout.
1.2 But
Cette…
1 Scope
1.1
This Standard applies to free-standing poles of ferrous metal, aluminum, polymeric, concrete, fibre- reinforced structures, and wood, and to their accessories, for use in the support of lighting equipment having ratings of 600 V and less, and intended to be installed in the commercial and industrial nonhazardous locations in accordance with the Rules of the Canadian Electrical Code…
Test method, marking requirements, and energy efficiency levels for three-phase induction motors
1 Scope
1.1 Application
This Standard specifies a test method for three-phase induction motors rated 0.746 kW and higher. The Standard also references energy efficiency levels for three-phase induction motors rated 0.746 kW up to 400 kW.
This Standard references energy efficiency levels for both NEMA and IEC motor designations. Efficiency requirements for units rated for operation at 60 Hz are…
1 Scope
1.1 Inclusions
This Standard specifies the test methods to be used in measuring the energy efficiency of small direct- current (dc), and single- and small three-phase alternating-current (ac) motors. It includes the following motor types:
a)
capacitor, permanent-split;
b)
capacitor, capacitor-start or capacitor-run;
c)
split phase;
d)
split phase start, capacitor-run;
e)…
Rendement thermique des générateurs autonomes d’air chaud à gaz, industriels et commerciaux
1 Domaine d’application
1.1 Généralités
Cette norme décrit les méthodes d’essai et les critères de rendement à utiliser pour déterminer les coefficients de performance de la saison de chauffage (CPTchauf. et CPGchauf.) des générateurs autonomes d’air chaud à gaz isolés et non isolés qui pourraient comporter ou non des caractéristiques permettant le fonctionnement en mode de ventilation et/ou de…
Canadian method for risk evaluation and assessment for railway systems
1 Scope
1.1 General
This Standard applies to proponents making any change to a railway system that is technical, operational, or organizational in nature.
The basic elements of the safety management system covered by this Standard include
a)
procedures for carrying out risk evaluation and analysis; and
b)
implementing risk control measures whenever a change in operating conditions or new…