Radio-frequency connectors. Part 22: R.F. two-pole bayonet coupled connectors for use with shielded ...
Specifies r.f. unmatched 2-pole connectors for use with a variety of balanced shielded cables having twin inner conductors which normally have a characteristic impedance ranging from 75 ohm to 130 ohm. Provides mating face and panel fixing dimensions, ratings, information on climatic category, gauging and type approval tests. These connectors are for low power, quick connect/disconnect…
1. Scope
1.1 This Standard applies to cord-connected electric clocks intended for use in household and other nonhazardous indoor dry locations in accordance with the Rules of the Canadian Electrical Code, Part I, and having a rating not exceeding 125 V ac and 30 W input and secondary circuits not exceeding 240 V.
1.2 This Standard includes both motor and electronically driven, di…
Applies to cabling and connectors used in battery electric road vehicles.
These recommendations are not applicable to the low tension wiring (e.g. 12 V) for the auxiliary and signalling accessories, such as horn, lighting, signalling lamps, wipers, etc., nor do they apply to connections between cells of the traction battery.
Provides general rules for all external wiring and connectors which are…
Electrical installations of buildings. Part 7: Requirements for special installations or locations. ...
Applies to the connection of data processing equipment to the electrical power installation of buildings, where the data processing equipment:
- has earth leakage current exceeding the limit specified in IEC 60950 and complies with IEC 60083;
- complies with the requirements of IEC 60950 which cover leakage current.
May also be applied where installations, other than data processing, such as…
Electrically Heated Bedding Appliances for Household Use
1. Scope
1.1 This Standard applies to cord-connected, electrically heated bedding such as blankets, comforters, quilts, sheets, mattresses, and mattress pads with associated control units, for household use, designed for nominal 120 V ac circuits and to be used in nonhazardous locations in accordance with the Rules of the Canadian Electrical Code, Part I.
1.2 This Standard does not apply…
Specifies requirements for handwheel or actuator-operated valves for general application including the following features: inside or outside screw stem; wedge or parallel obturator; metallic or elastomeric obturator seatings; metallic or elastomeric body seatings; ferrous metal and/or copper alloy trims; bolted bonnet connection; flanged ends. Covers valves of the nominal sizes (DN) from 40 to…
Road vehicles — Hydraulic pressure test connection for braking equipment
Specifies the main characteristics of connections used for checking response times and pressure levels for braking equipment fitted on road vehicles, and gives the open space requirements that shall surround the pressure test connection and the protection against corrosion. Passenger cars and their derivatives are excluded. This second edition cancels and replaces the first edition (1976).
Véhicules routiers — Raccords de contrôle de pression pour systèmes de freinage hydraulique
La présente norme internationale spécifie les caractéristiques dimensionnelles essentielles d'une connexion utilisée pour le contrôle des temps de réponse et des niveaux de pression pour les équipements de freinage montés sur les véhicules routiers à l'exception des voitures particulières et de leurs types dérivés. Pour assurer une liberté absolue de fuite, et ainsi parfaire le…