Energy performance of room air conditioners
Scope 1.1 This Standard specifies the energy performance test method for room air conditioners and specifies minimum efficiency levels. 1.2 This Standard covers room air conditioners powered by a single-phase electric current and rated at 10.55 kW (36 000 Btu/h) cooling capacity and below at standard rating conditions. 1.3 This Standard does not apply to the rating and testing of individual…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2014-01-31
Code(s) de l'ICS :
23.120
Automatic electrical controls for household and similar use - Part 2-15: Particular requirements for...
Scope and normative references This clause of Part 1 is replaced as follows: 1.1 This part of IEC 60730 applies to automatic electrical air flow, water flow and water level sensing controls for use in, or in association with, boilers with a maximum pressure rating of 2 000 kPA (20 bar) and equipment for general household and similar use including controls for heating, air- conditioning and…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2014-01-31
Code(s) de l'ICS :
97.120
Self-retracting devices
Scope 1.1 This Standard specifies the requirements for all self-retracting devices (SRDs) used as connecting components in fall protection systems. SRDs are further classified in this Standard according to method of use. 1.2 The equipment specified in this Standard is intended for users at risk of falls from height while at work. 1.3 This Standard outlines requirements for labeling products…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
13.340.60
Standard for Smoke Alarms
1 Scope 1.1 These requirements cover electrically operated single and multiple station smoke alarms intended for open area protection in indoor locations, in accordance: a) Installation of Smoke Alarms, CAN/ULC-S553; b) National Building Code of Canada; and c) National Fire Code of Canada. 1.2 A single station smoke alarm (e.g. ionization-type, photoelectric-type, smoke alarm with…
Éditeur :
ULC
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
13.220.20; 13.320
Plumbing fixtures with pumped waste and macerating toilet systems
Scope 1.1 This Standard establishes physical, performance, and testing requirements applicable to plumbing fixtures with pumped waste, macerating toilet systems, and related components. Such systems are intended to collect waste from a single fixture such as a water closet, lavatory, shower, or bathtub and pump these wastes to some point in the sanitary drainage system. 1.2 The purpose of…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
91.140.70
Cord sets and power-supply cords
Scope 1.1 This Standard specifies the requirements for cord sets and power-supply cords employing molded-on or assembled-on fittings, rated 600 V maximum, and intended for use in non-hazardous locations in accordance with the Canadian Electrical Code, Part I, CSA C22.1-12 and General Requirements-Canadian Electrical Code, Part II, CSA C22.2 No. 0-10. 1.2 This Standard also specifies the…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
29.060.10; 29.120.30
Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for ...
1 Scope and normative references This clause of part 1 is applicable except as follows: 1.1 Replacement: This part of IEC 60730 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use. This part 2-5 is applicable to a complete…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
29.130.01
Medical device software - Software life cycle processes (Adopted CEI/IEC 62304:2006, first edition, ...
Scope 1.1 * Purpose This standard defines the life cycle requirements for MEDICAL DEVICE SOFTWARE. The set of PROCESSES, ACTIVITIES, and TASKS described in this standard establishes a common framework for MEDICAL DEVICE SOFTWARE life cycle PROCESSES. 1.2 * Field of application This standard applies to the development and maintenance of MEDICAL DEVICE SOFTWARE. This standard applies to the…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2014-01-31
Code(s) de l'ICS :
11.040
Medical devices - Application of usability engineering to medical devices (Adopted IEC 62366:2007, f...
1 * Scope This International Standard specifies a PROCESS for a MANUFACTURER to analyse, specify, design, VERIFY and VALIDATE USABILITY, as it relates to SAFETY of a MEDICAL DEVICE. This USABILITY ENGINEERING PROCESS assesses and mitigates RISKS caused by USABILITY problems associated with CORRECT USE and USE ERRORS, i.e. NORMAL USE. It can be used to identify but does not assess or mitigate…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
11.040
Anaesthetic and respiratory equipment — Tracheal tubesand connectors
Scope This International Standard provides essential performance and safety requirements for oro-tracheal and naso-tracheal tubes and tracheal tube connectors. Tracheal tubes with walls reinforced with metal or nylon, tracheal tubes with shoulders, tapered tracheal tubes, tracheal tubes with means for suctioning or monitoring or delivery of drugs or other gases, and the many other types of…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2014-01-31
Code(s) de l'ICS :
11.040.10