Health informatics — Information security management in health using ISO/IEC 27002
ISO 27799:2016 gives guidelines for organizational information security standards and information security management practices including the selection, implementation and management of controls taking into consideration the organization's information security risk environment(s).
It defines guidelines to support the interpretation and implementation in health informatics of ISO/IEC 27002…
ISO 10254:2016 defines the terms relating to air cargo and aircraft ground equipment, as used in the other International Standards in these areas.
NOTE The term "weight" is used throughout ISO 10254:2016 instead of the correct technical term "mass", in order to conform to current commercial usage.
The terms and abridged definitions of ISO 10254:2016 are primarily…
1.1
This Standard applies to wet-process porcelain and toughened glass suspension-type insulators used on ac overhead power lines with a nominal voltage greater than 1000 V and a frequency not greater than 100 Hz.
This Standard applies to single insulator units only and does not apply to long rod insulators.
1.2
This Standard specifies provisions for
a)
the mechanical, electrical, and…
Composite suspension insulators for overhead lines > 75 kV
1.1
This Standard applies to suspension and dead-end composite insulators used on ac overhead transmission lines with a nominal voltage greater than 75 kV and a frequency not greater than 100 Hz.
1.2
This Standard specifies
a)
insulator characteristics (mechanical, electrical, and dimensional) and prescribe the conditions under which these characteristics are to be verified;
b)
test…
Dead-end/suspension composite insulators for overhead lines = 75 kV For
1.1
This Standard covers the requirements for dead-end/suspension composite insulators used on overhead distribution lines operating at nominal voltages up to and including 75 kV. Dead-end insulators support the line conductor horizontally. Suspension insulators support the line conductor vertically. Both are subjected to tensile and torsional loads.
These composite insulators are intended to…
Line post composite insulators for overhead distribution lines = 75 kV
1.1
This Standard covers the requirements for line post composite insulators used on overhead distribution lines operating at nominal voltages up to and including 75 kV. Line post insulators support the line conductor horizontally or vertically. They are subjected to tensile, cantilever, and compressive loads.
These composite insulators are intended to operate in a service environment within a…
1.1
This Standard covers the requirements for guy composite insulators used in guy wires on overhead distribution lines operating at nominal voltages up to and including 75 kV. Guy insulators insulate or isolate guy wires for corrosion protection, higher insulation levels, clearances for maintenance and normal operation, and safety for the public and workers (joint-use). Guy composite insulators…
1.1
This Standard applies to mechanical flue-gas exhausters intended to be installed in a flue pipe,
breeching, or chimney and serving appliances burning natural gas, propane, or fuel oil.
1.2
This Standard covers the mechanical and electrical features of mechanical flue-gas exhausters for indoor
or outdoor installations.
1.3
This Standard classifies mechanical flue-gas exhausters as:
a)…
Reduction of fugitive and vented emissions for upstream petroleum and natural gas industry systems
1.1
This Standard specifies criteria to develop emission reduction practices and programs.
1.2
This Standard addresses fugitive and vented emissions from point sources in the following sectors (see
Figure 1) of the upstream oil and gas industry from wells, pipelines, and facilities associated with
a) crude oil production and shale oil;
b) oil sands – in situ bitumen production, including…
Sterilization of health care products — Radiation — Part 2:Establishing the sterilization dose
This part of ISO 11137 specifies methods for determining the minimum dose needed to achieve a specified
requirement for sterility and methods to substantiate the use of 25 kGy or 15 kGy as the sterilization
dose to achieve a sterility assurance level, SAL, of 10-6. This part of ISO 11137 also specifies methods of
sterilization dose audit used to demonstrate the continued effectiveness of the…