Telecommunications and information exchange between systems - Recursive inter-network architecture -...
This document defines the procedure executed by a Member of a distributed inter-process communication (IPC) facility (DIF) or distributed application facility (DAF) to initialize a new Member as a fully functioning Member. This document defines the procedure for a new Member to enrol when the new Member was recently a Member of the DIF or DAF. This document is defined for use with DIFs, but it…
Telecommunications and information exchange between systems - Recursive inter-network architecture -...
This document provides a delimiting module that defines a mechanism for encoding Service Data Units (SDUs), the amount of data passed across the layer boundary within Protocol Data Units (PDUs), the amount of data sent to its peer. It is not necessary to use this document if each PDU carries precisely one SDU.
Health informatics — HL7 Personal Health Record System Functional Model, Release 2 (PHR-S FM)
ISO/HL7 16527 PHR-S FM:2016 defines a standardized model of the functions that may be present in PHR Systems.
It is beyond the scope of the PHR system to control the use (or intended use) of PHR data. On the contrary, it is within the scope of the PHR system to manage the authorization of an individual (or other application). Those parties are then responsible for using the data for appropriate (…
Radiological protection — Content of input data for the statistical analysis of dose records of indi...
The objective of this document is to promote the harmonization of data and information reporting formats in order to provide the basis for the evaluation of occupational exposure with a view to allow for benchmarking capacity at the user level, technical review level, country level and global level (such as UNSCEAR) database or register on occupational exposure. Activity sectors and occupations (…
1 Scope
1.1 Purpose
The purpose of this Standard is to minimize the risk of personal injury by providing minimum requirements for the design, construction, installation, inspection, and maintenance of the mechanical refrigeration systems and volatile direct refrigeration systems specified in Clauses 1.2.1and 1.2.2.
Note: This Standard does not directly address protection of property and…
Compressed natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to
a)
the design, location, construction, operation, operator training, and maintenance of CNG vehicle refuelling stations; and
b)
CNG bulk transport filling and decanting stations, including
i)
those that are fixed or mobile and intended for private or public dispensing operations; and
ii)
bulk transport filling and decanting stations that feed…
Liquefied natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to
a)
the design, location, construction, operation, operator training, and maintenance of LNG refuelling stations;
b)
LNG mobile refuelling units (MRUL) or LNG portable refuelling units (PRUL) with single containment storage tanks up to 265 m3 (70 000 gal) water capacity employed for vehicle LNG dispensing operations;
c)
shop-fabricated and…
1 Scope
1.1
This Standard applies to portable luminaires, intended for use in dry, damp, and wet locations, and intended to be used in accordance with the Rules of CSA C22.1, Canadian Electrical Code, Part I, in non- hazardous locations, on a nominal 120 V system and 15 or 20 A branch circuits, or on the load side of a Class 2, LED Class 2, or safety extra-low voltage (SELV) circuit.
1.2
This…
Benchmark energy factor (BEF) for industrial air movement systems
1 Scope
1.1 Inclusions
This Standard is intended for industrial air handling systems with the following characteristics:
a)
systems with energy consumption greater than 500 000 kWh per year;
b)
systems with air flow greater than 9.4 m3/s (20 000 cfm);
c)
air movement systems with a maximum energy output limit of 25 kJ/kg of air, which is equivalent to a maximum pressure ratio of 1.3 per…
Minimum efficiency values for liquid-filled distribution transformers
1 Scope
1.1 General
This Standard specifies energy efficiencies for liquid-filled distribution transformers. The total ownership cost (TOC) methodology is recommended as the means for achieving these energy efficiencies, particularly for use by electric utilities. This Standard also specifies an optimal method for non-utility users, based on a modified TOC methodology that meets the conditions…