1 Scope
1.1 Purpose
This Standard specifies technical requirements on how to make buildings and the exterior built environment accessible and safely usable by persons with physical, sensory, or cognitive disabilities.
1.2 Application
This Standard describes technical requirements that can be used in the design and construction of new facilities or exterior environments, or in modifications to…
1 Scope
1.1
This Standard specifies the requirements for cord sets and power-supply cords employing molded-on or assembled-on fittings, rated 600 V maximum, and intended for use in non-hazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I, and CAN/CSA-C22.2 No. 0, General Requirements—Canadian Electrical Code, Part II.
1.2
This Standard also specifies the…
1 Scope
1.1
This Standard applies to single- and multiple-conductor fire alarm and signal cables with a maximum nominal voltage rating of 300 V and a minimum temperature rating of 60 °C for use in buildings and other structures in dry, damp, or wet locations in accordance with the Canadian Electrical Code, Part I.
1.2
Because other CSA Group Standards specify requirements for certain…
1 Scope
1.1
This Standard applies to high density polyethylene (HDPE) conduit, HDPE conduit with conductors, and polyethylene dual-wall (PEDW) corrugated conduit, intended for use at a continuous operating temperature of 75 °C or 90 °C, for installation in accordance with the Rules of the Canadian Electrical Code, Part I, for direct burial or encasement in concrete or masonry in ordinary (non-…
Energy performance of refrigerated bottled or canned beverage vending machines
1 Scope
1.1
This Standard specifies energy performance requirements for self-contained, refrigerated bottled, or canned beverage vending machines that actively cool bottled, canned, or other sealed refrigerated beverages.
1.2
This Standard specifies
a)
uniform procedures for measuring energy consumption;
b)
maximum daily energy consumption levels; and
c)
refrigerated volume, vending…
1 Scope
1.1
This Standard applies to newly produced household cooking gas appliances (see Clause 3, Definitions), hereinafter referred to as units or appliances, constructed entirely of new, unused parts and materials. These appliances may be floor supported or built-in.
1.2
This Standard applies to household cooking gas appliances:
a)
for use with natural gas;
b)
for use with…
1 Scope
1.1
This Standard specifies the electrical, mechanical, dimensional characteristics, test methods, and acceptance criteria for solid-core and cavity core ceramic and glass type station post insulators for outdoor service in electrical installations or equipment operating with a rated voltage greater than 1000 V and a rated frequency not greater than 100 Hz.
Note: Hollow core insulators…
1 Scope
1.1
This Standard specifies the electrical, mechanical, dimensional characteristics, test methods, and acceptance criteria for composite station post insulators for outdoor service, operating at nominal voltages greater than 1000 V and frequency not greater than 100 Hz. Station post insulators are mainly used as support or operating elements in switching equipment, or as bus bar or…
Systems and software engineering — Life cycle management — Part 1: Guidelines for life cycle managem...
This document provides guidelines for the life cycle management of systems and software, complementing the processes described in ISO/IEC/IEEE 15288 and ISO/IEC/IEEE 12207. This document:
— addresses systems concepts and life cycle concepts, models, stages, processes, process application, key points of view, adaptation and use in various domains and by various disciplines;
—…
Geotechnical investigation and testing — Testing of geotechnical structures — Part 1: Testing of pil...
This document establishes the specifications for the execution of static pile load tests in which a single pile is subjected to an axial static load in compression in order to define its load-displacement behaviour.
This document is applicable to vertical piles as well as raking piles.
All types of piles are covered by this document. The tests considered in this document are limited to maintained…