Paper and board — Measurement of water contact angle by optical methods
This document specifies the method for optical assessment of the contact angle between water and the surface of paper and board, where the process of droplet formation, application to planar substrates, or measurement of the droplet shape in contact with the solid is performed by automated equipment.
The limits of measurement are determined by the capabilities of the instrumentation used. The…
Ships and marine technology — Low-location lighting (LLL) on passenger ships — Arrangement
This document specifies the requirements for the approval, installation and maintenance of low-location lighting systems as defined in Chapter II-2, Regulation 13.3.2.5.1 of the International Convention for the Safety of Life at Sea, 1974 (SOLAS 74), as amended in 2000, and detailed in Chapter 11 of the International Code for Fire Safety Systems (FSS Code).
Cork bark selected as bottling product — Part 1: Sensory evaluation — Methodology for sensory evalua...
This document defines a test method for the detection, qualification and possible assessment of odours/flavours exogenous to cork bark selected as bottling product in contact with beverages, still, sparkling and sparkling wines, alcohols and spirits, beers and ciders.
This document is applicable to:
— cork bark selected as bottling product in all its forms;
— all cork components of cork…
High-voltage switchgear and controlgear - Part 312: Guidance for the transferability of type tests o...
IEC TR 62271-312:2021(E) refers to high-voltage / low-voltage prefabricated substations (hereinafter prefabricated substations) as specified in IEC 62271-202:2014.
This document, among other options as agreed between manufacturer and user, can be used for the transferability of type tests performed on one or more prefabricated substations with a defined set of ratings and arrangement of…
Electronic displays - Part 2-1: Measurements of optical characteristics - Fundamental measurements
IEC 62977-2-1:2021(E) specifies standard measurement conditions and measuring methods for determining the optical characteristics of electronic display modules and systems. These methods apply to emissive and transmissive direct view displays that render real 2D images on a flat panel. This document evaluates the optical characteristics of these displays under darkroom conditions. This document…
Performance requirements for climate resilience of low slope membrane roofing systems
1 Scope
1.1
This Standard outlines requirements for low slope membrane roofing systems (LSMRS) when identified as “silver” and “gold” performance level based on the climate severity and resilience requirements.
Note: The National Building Code of Canada and the National Energy Code of Canada for Buildings provides “bronze” requirements for LSMRS.
1.2
This Standard is intended to be used by…
Compressed natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to all compressed natural gas (CNG) refuelling stations, including those that are fixed or mobile and intended for private or public dispensing operations.
1.2 Exclusions
This Code does not apply to
a)
refuelling vehicles with liquefied natural gas (LNG). Refuelling vehicles with LNG is addressed in CSA B108.2. However, when an LNG facility has…
Liquefied natural gas refuelling stations installation code
1 Scope
1.1 Inclusions
This Code applies to
a)
the design, location, construction, operation, operator training, and maintenance of LNG refuelling stations, including LNG mobile refuelling units (MRUL), with single containment storage tanks up to 265 m3 (70 000 gal) water capacity employed for vehicle LNG dispensing operations;
b)
shop-fabricated and assembled refuelling stations when used…
1 Scope
1.1 General
This Code sets out the minimum provisions for the installation, extension, alteration, and renewal of hydronic heating systems.
1.2 Inclusions
This Code applies to open and closed hydronic heating systems. These systems include
a)
hydronic space heating;
b)
radiant heating (wall, floor, and ceiling);
c)
convectors;
d)
fan coils;
e)
combination potable-water-…