Electrical relays - Tests and measurements - Part 49: Long term stability of sealing
IEC 63522-49:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for long term stability of sealing.
Information technology — SoftWare Hash IDentifier (SWHID) Specification V1.2
This specification defines a standard data format for referencing software artifacts that match the data model of modern distributed version control systems.
This format includes the typical tree-like structure of a filesystem hierarchy, but also, special nodes to track revisions and releases, as well as the full status of a version control system, with all its development branches.
A key…
Information technology - SoftWare Hash IDentifier (SWHID) Specification V1.2
This specification defines a standard data format for referencing software artifacts that match the data model of modern distributed version control systems.
This format includes the typical tree-like structure of a filesystem hierarchy, but also, special nodes to track revisions and releases, as well as the full status of a version control system, with all its development branches.
A key…
Electrical relays - Tests and measurements - Part 24: Load transfer
IEC 63522-24:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of DUTs to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a test to check that a multipole relay is capable of transferring one source to another.
Electrical relays - Tests and measurements - Part 56: Ball Pressure test
IEC 63522-56:2025 This part of IEC 63522 is used for testing along with the appropriate severities and conditions for measurements and tests designed to assess the ability of specimens to perform under expected conditions of transportation, storage and all aspects of operational use.
The object of this test is to define a standard test method for evaluation of appropriate materials to withstand…
Electrical relays - Tests and measurements - Part 44: Corrosive atmosphere due to salt mist
IEC 63522-44:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. The object of this test is to define a standard test method for salt mist.
Electrical relays - Tests and measurements - Part 37: Terminal temperature rise at rated load
IEC 63522-37:2025 This part of lEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. The object of this document is to define a standard test method to measure terminal temperature rise at rated load, included solder terminals, flat quick-connect terminations…
Electrical relays - Testing and measurement - Part 38: Mechanical interlock
IEC 63522-38:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use.
This document defines a standard test method for mechanical interlock.
Electrical relays - Testing and measurement - Part 27: Electrical contact noise
IEC 63522-27:2025 This part of IEC 63522 is used for testing all kinds of electrical relays and for evaluating their ability to perform under expected conditions of transportation, storage and all aspects of operational use. This document defines a standard test method for electrical contact noise.
Optical fibre cables - Part 1-216: Generic specification - Basic optical cable test procedures - Env...
IEC 60794-1-216:2025 defines test procedures to ensure the filling and flooding compounds will not flow from a filled or flooded fibre optic cable, at stated temperatures. NOTE The environmental testing of optical cable would be valuable for some applications. Useful information about suitable test methods can be found in the optical fibre standards IEC 60794-1-2.
This document partially cancels…