1 Scope
This National Standard of Canada applies to two grades of kerosene-type aviation turbine fuel (grades JET A and
JET A-1), consisting of conventional hydrocarbons, synthetic hydrocarbons, naturally occurring non-hydrocarbons
and additives as specified herein.
The fuels are normally used in civil aviation operations. The two grades differ only in freezing point. Grade JET A
has a…
Aviation turbine fuel (Military grades F-34, F-37 and F-44)
1 Scope
This National Standard of Canada applies to three grades of aviation turbine fuel (military grades F-34, F-37 as
its equivalent, and F-44) consisting of conventional hydrocarbons, synthetic hydrocarbons, naturally occurring
non-hydrocarbons and additives as specified herein.
Grade F-34 is a kerosene-type aviation turbine fuel, and grade F-44 is a high-flash kerosene-type aviation…
Scope
This National Standard of Canada applies to two types of automotive fuel: type 1, 50% to 85% by volume denatured
fuel ethanol with gasoline and type 2, 20% to 25% by volume denatured fuel ethanol with gasoline. Both types are
for use in flexible-fuel vehicles over a wide range of climatic conditions.
Users of this standard are advised to consult the owner’s manual and/or the original…
1 Scope
1.1 Inclusions
This Standard defines the requirements for performance, installation and application, and performance verification of mechanical ventilation systems. This Standard applies to systems that are capable of providing minimum controlled rates of outdoor air to the habitable spaces of those single-family dwelling units that
a)
fall within the Scope of Part 9 of the National…
Scope
This National Standard of Canada describes two grades of propane used for fuel purposes. These grades consist
mainly of hydrocarbons containing three carbon atoms.
Grade 1 is intended for use in internal combustion engines and for general industrial and commercial fuel applications.
Grade 1 maintains a minimum octane quality by limiting concentrations of low-octane components (see 6.5…
Scope
This National Standard of Canada applies to four types of middle distillate fuel oils that are suitable for use in liquid
fuel burning equipment without preheating [types 0, 1, 2 and 2(B6-B20)], and three types of fuel oils that contain
residual fuel components that require preheating (types 4, 5 and 6).
The heating fuel oils covered by this standard are intended for use in oil burning…
Équipement à moteur pour la distribution de gaz de pétrole liquéfié
1 Domaine d’application
1.1
Ces exigences s’appliquent à l’équipement à moteur pour la distribution du gaz de pétrole liquéfié dans le réservoir de stockage du carburant d’un véhicule où le gaz est principalement utilisé comme carburant du moteur.
1.2
Les caractéristiques électriques des distributeurs à moteur sont décrites :
a)
Aux États-Unis : UL 1238, Standard for Control Equipment for…
Scope
1.1 These requirements cover an energy storage system (ESS) that is intended to receive and store
energy in some form so that the ESS can provide electrical energy to loads or to the local/area electric
power system (EPS) when needed. Electrochemical, chemical, mechanical, and thermal ESS are covered
by this Standard. The ESS shall be constructed either as one unitary complete piece of…
Domaine d’application
1.1 Ces exigences concernent un système de stockage de l’énergie (ESS) destiné à recevoir de
l’énergie et à l’emmagasiner sous une forme qui peut approvisionner en énergie électrique, selon la
nécessité, des charges ou le système d’alimentation électrique (EPS) local ou d’un secteur. Les ESS
électrochimiques, chimiques, mécaniques et thermiques sont couverts par la…
Scope
1.1 This Standard sets forth requirements for smoke detectors and accessories, including mechanical
guards to be employed in ordinary indoor locations in accordance with the following:
a) In Canada only:
1) Standard for the Installation of Fire Alarm Systems, ULC-S524;
2) National Building Code of Canada; and
3) National Fire Code of Canada.
b) In the United States only: