Textiles — Test method for assessing the smoothness appearance of fabrics after cleansing
ISO 7768:2009 specifies a method for assessing the retention of the original smooth appearance, after one or several cleansing treatments, of the fabrics tested.
This method has been developed for use primarily with Type B domestic washing machines, as defined in ISO 6330, in the cleansing process. However, it may be possible to use it with Type A machines, as defined in the same International…
Non-invasive sphygmomanometers - Part 2: Clinical validation of automated measurement type
ISO 81060-2:2009 is applicable to all sphygmomanometers that sense or display pulsations, flow or sounds for the estimation, display or recording of blood pressure. These sphygmomanometers need not have automatic cuff inflation. ISO 81060-2:2009 covers sphygmomanometers intended for use in all patient populations (e.g. all age and weight ranges), and all conditions of use (e.g. ambulatory blood…
Explosive atmospheres - Part 18: Equipment protection by encapsulation "m"
IEC 60079-18:2009 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 60079-18:2009 gives the specific requirements for the construction, testing and marking of electrical equipment…
Preface
This is the harmonized CSA and UL standard for Electrical Quick-Connect Terminals. It is the Second edition of CSA-C22.2 No. 153-09 and the Eighth edition of UL 310. This edition of CSA C22.2 No. 153 supersedes the previous edition published in 1981 under the title Quick-Connect Terminals. This edition of UL 310 supersedes the previous edition published May 27, 2003.
Scope
1.1 This…
Fibre-cement flat sheets — Product specification and test methods
ISO 8336:2009 specifies methods for the inspection and testing of fibre-cement flat sheets and gives the acceptance conditions for their use in one or more of the following applications:
external wall and ceiling finishes;
internal wall and ceiling finishes;
internal and external backing sheets.
Products covered by ISO 8336:2009 can be used for other purposes, provided they comply with the…
Non-invasive sphygmomanometers — Part 2: Clinical validation of automated measurement type
ISO 81060-2:2009 is applicable to all sphygmomanometers that sense or display pulsations, flow or sounds for the estimation, display or recording of blood pressure. These sphygmomanometers need not have automatic cuff inflation. ISO 81060-2:2009 covers sphygmomanometers intended for use in all patient populations (e.g. all age and weight ranges), and all conditions of use (e.g. ambulatory blood…
Textiles — Method for assessing appearance of apparel and other textile end products after domestic ...
ISO 15487:2009 specifies a method of test for evaluating the smoothness appearance of flat fabric and seams, and the retention of pressed-in creases in garments and other textile products after one or several domestic washing and drying treatments. It is applicable to any washable textile end product of any fabric construction. Techniques for seaming and creasing are not included since the…
In vitro diagnostic medical devices — Measurement of quantities in samples of biological origin — Re...
ISO 15194:2009 specifies requirements for certified reference materials and the content of their supporting documentation, in order for them to be considered of higher metrological order in accordance with ISO 17511. It is applicable to certified reference materials classifiable as primary measurement standards, secondary measurement standards and international conventional calibrators that…
Fibre-cement slates and fittings — Product specification and test methods
ISO 9125:2009 specifies technical requirements and methods for the inspection and testing of fibre-cement slates and shingles and their fibre-cement fittings, designed to protect the weather-exposed surfaces on roofs and claddings of buildings.
Products covered by ISO 9125:2009 can be used for other purposes provided they comply with the appropriate national or international application code or…
Rubber hoses and hose assemblies — Wire-braid-reinforced hydraulic types for oil-based or water-base...
ISO 1436:2009 specifies requirements for six types of wire-braid-reinforced hose and hose assembly of nominal size from 5 to 51 plus, for one of the five types (type R2ATS), nominal size 63. They are suitable for use with water-based hydraulic fluids HFC, HFAE, HFAS and HFB as defined in ISO 6743‑4 at temperatures ranging from to -40 °C to +60 °C or oil-based hydraulic fluids HH, HL, HM, HR and…