Live Working - Guidelines for the Installation of Transmission Line Conductors and Earthwires - Stri...
This National Standard of Canada is based on International Standard CEI/IEC 61328:2003.
This National Standard of Canada provides recommendations for the selection and testing where necessary of conductor stringing equipment and accessory items used for the installation of overhead conductors and overhead earthwires…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61010-2-020:2006.
1 Scope and object
This clause of Part 1 is applicable except as follows:
1.1 Scope
Replacement:
This Part 2 is applicable to electrically powered LABORATORY CENTRIFUGES.
NOTE If all or part of the equipment falls within the scope of one or more other Part 2 standards of IEC 61010 as well as…
Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to con...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-4-6:2003.
1 Scope and object
This part of IEC 61000-4 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 9 kHz up to 80 MHz. Equipment not having at least one…
Electromagnetic compatibility (EMC) - Part 3-13: Limits - Assessment of emission limits for the conn...
This National Standard of Canada is equivalent to International Standard IEC/TR 61000-3-13:2008.
1 Scope
This part of IEC 61000 provides guidance on principles which can be used as the basis for determining the requirements for the connection of unbalanced installations (i.e. three-phase installations causing voltage unbalance) to MV, HV and EHV public power systems (LV installations are covered…
Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commer...
This National Standard of Canada is equivalent to International Standard CEI/IEC 61000-6-1:2005.
1 Scope and object
This part of IEC 61000 for EMC immunity requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Immunity requirements in the frequency range 0 Hz to 400 GHz are covered. No tests need to be…
Sound and television broadcast receivers and associated equipment - Radio disturbance characteristic...
This National Standard of Canada is equivalent to International Standard CEI/IECCISPR 13:2001.
1 Scope and object
This International Standard applies to the generation of electromagnetic energy from sound and television receivers for the reception of broadcast and similar transmissions and from associated equipment. The frequency range covered extends from 9 kHz to 400 GHz.
No…
Plastics — Instrumental determination of radiant exposure in weathering tests — General guidance and...
ISO 9370:2009 specifies methods for the instrumental measurement of irradiance on a planar surface. This includes not only natural solar radiation but also intensified natural solar radiation and radiation produced by laboratory light sources.
For measurement of solar radiation for natural weathering and accelerated natural weathering, instrumental techniques include the continuous measurement of…
Digital addressable lighting interface - Part 101: General requirements - System
IEC 62386-101:2009 specifies a protocol for control by digital signals of electronic lighting equipment used on a.c. or d.c. supplies. This Part 101 is intended to be used in conjunction with Part 102, which contains general requirements for the relevant product type (control gear), and with the appropriate part 2XX (particular requirements for control gear) containing clauses to supplement or…
Digital addressable lighting interface - Part 102: General requirements - Control gear
IEC 62386-102:2009 specifies a protocol and methods of test for the control by digital signals of electronic control gear for use on a.c. or d.c. supplies. This Part 102 is intended to be used in conjunction with Part 101, which contains general requirements for the relevant product type (system), and with the appropriate part 2XX (particular requirements for control gear) containing clauses to…
ISO 4354:2008 describes the actions of wind on structures and specifies methods of calculating characteristic values of wind loads for use in designing buildings, towers, chimneys, bridges and other structures, as well as their components and appendages. The loads are suitable for use in conjunction with ISO 2394 and other International Standards concerned with wind loads. In particular, ISO 4354…