ISO 7186:2011 specifies the requirements and test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings:
- to convey surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems;
- operating without pressure (gravity sewers…
Medical electrical equipment — Part 2-5: Particular requirements for the basic safety and essential ...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-5:2009.
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ULTRASONIC PHYSIOTHERAPY EQUIPMENT as defined in 201.3.216, hereafter referred to as
ME EQUIPMENT.
This standard only relates to ULTRASONIC PHYSIOTHERAPY EQUIPMENT employing a…
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-41:2009.
201.1.1 *Scope
Replacement:
This particular standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL
LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT.
This particular standard does not apply to
– headlights;
– endoscopes, laparoscopes and…
Medical electrical equipment — Part 2-18: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-18:2009.
Clause 1 of the general standard1) applies, except as follows:
201.1.1 * Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ENDOSCOPIC EQUIPMENT together with its INTERCONNECTION CONDITIONS and INTERFACE
CONDITIONS.
The general…
Medical electrical equipment — Part 1-11: General requirements for basic safety and essential perfor...
This National Standard of Canada is equivalent to International Standard IEC 60601-1-11:2010.
1.1 * Scope
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as
ME EQUIPMENT and ME SYSTEMS, which are intended by their MANUFACTURER for use in the
HOME HEALTHCARE ENVIRONMENT, as…
Medical electrical equipment — Part 2-52: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-52:2009.
201.1.1 * Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
MEDICAL BEDS intended for adults, hereafter referred to as MEDICAL BED as defined in
201.3.212.
If a clause or subclause is specifically intended to be applicable to a MEDICAL BED only,…
Medical electrical equipment — Part 2-1: Particular requirements for thebasic safety and essential p...
201.1 Scope, object and related standards
Clause 1 of the general standard1) applies, except as follows:
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to
50 MeV, used for treatment of PATIENTS.
This particular standard, with the…
LIVE WORKING – MINIMUM REQUIREMENTS FOR THE UTILIZATION OF TOOLS, DEVICES AND EQUIPMENT
1 Scope
This International Standard gives the minimum requirements relative to specification,
manufacture, selection, application and maintenance of tools, devices and equipment for live
working.
It provides the type of information which is useful to skilled persons in order to make the use
of tools, devices and equipment safer.
This type of information includes:
• the characteristics of tools,…
Medical electrical equipment — Part 2-54: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-54:2009.
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ME EQUIPMENT and ME SYSTEMS intended to be used for projection RADIOGRAPHY and
RADIOSCOPY. IEC 60601-2-43 applies to ME EQUIPMENT and ME SYSTEMS intended to be used
for…
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-11:2011 is now available as IEC Standards+ 60079-11:2011 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition.
IEC 60079-11:2011 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended…