Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 4001 - 4010 de 9526
Ductile iron products for sewerage applications
ISO 7186:2011 specifies the requirements and test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings: - to convey surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems; - operating without pressure (gravity sewers…
Éditeur :
ISO
Statut :
Publié
Date de publication :
2011-07-07
Code(s) de l'ICS :
77.140.80; 93.030
Medical electrical equipment — Part 2-5: Particular requirements for the basic safety and essential ...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-5:2009. 201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ULTRASONIC PHYSIOTHERAPY EQUIPMENT as defined in 201.3.216, hereafter referred to as ME EQUIPMENT. This standard only relates to ULTRASONIC PHYSIOTHERAPY EQUIPMENT employing a…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.040.60
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-41:2009. 201.1.1 *Scope Replacement: This particular standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT. This particular standard does not apply to – headlights; – endoscopes, laparoscopes and…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.040.20; 11.040.20
Medical electrical equipment — Part 2-18: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-18:2009. Clause 1 of the general standard1) applies, except as follows: 201.1.1 * Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ENDOSCOPIC EQUIPMENT together with its INTERCONNECTION CONDITIONS and INTERFACE CONDITIONS. The general…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.040.50
Medical electrical equipment — Part 1-11: General requirements for basic safety and essential perfor...
This National Standard of Canada is equivalent to International Standard IEC 60601-1-11:2010. 1.1 * Scope This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as ME EQUIPMENT and ME SYSTEMS, which are intended by their MANUFACTURER for use in the HOME HEALTHCARE ENVIRONMENT, as…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.040
Medical electrical equipment — Part 2-52: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-52:2009. 201.1.1 * Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of MEDICAL BEDS intended for adults, hereafter referred to as MEDICAL BED as defined in 201.3.212. If a clause or subclause is specifically intended to be applicable to a MEDICAL BED only,…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.140
Medical electrical equipment — Part 2-1: Particular requirements for thebasic safety and essential p...
201.1 Scope, object and related standards Clause 1 of the general standard1) applies, except as follows: 201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to 50 MeV, used for treatment of PATIENTS. This particular standard, with the…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.040.60
LIVE WORKING – MINIMUM REQUIREMENTS FOR THE UTILIZATION OF TOOLS, DEVICES AND EQUIPMENT
1 Scope This International Standard gives the minimum requirements relative to specification, manufacture, selection, application and maintenance of tools, devices and equipment for live working. It provides the type of information which is useful to skilled persons in order to make the use of tools, devices and equipment safer. This type of information includes: • the characteristics of tools,…
Éditeur :
ULC
Statut :
Norme
Date de publication :
2011-06-30
Code(s) de l'ICS :
13.260; 13.260
Medical electrical equipment — Part 2-54: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-54:2009. 201.1.1 Scope Replacement: This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of ME EQUIPMENT and ME SYSTEMS intended to be used for projection RADIOGRAPHY and RADIOSCOPY. IEC 60601-2-43 applies to ME EQUIPMENT and ME SYSTEMS intended to be used for…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2011-06-30
Code(s) de l'ICS :
11.040.50
Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60079-11:2011 is now available as IEC Standards+ 60079-11:2011 which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60079-11:2011 specifies the construction and testing of intrinsically safe apparatus intended for use in an explosive atmosphere and for associated apparatus, which is intended…
Éditeur :
IEC
Statut :
Révisé
Date de publication :
2011-06-29
Code(s) de l'ICS :
29.260.20

Spacer