Semiconductor devices - Mechanical and climatic test methods - Part 40: Board level drop test method...
IEC 60749-40:2011 is intended to evaluate and compare drop performance of a surface mount semiconductor device for handheld electronic product applications in an accelerated test environment, where excessive flexure of a circuit board causes product failure. The purpose is to standardize test methodology to provide a reproducible assessment of the drop test performance of a surface mounted…
Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF connectors
IEC 61169-35:2011 provides information and rules for preparation of detail specification of 2,92 series RF coaxial connectors together with the pro-forma blank detail specification. It also prescribes mating face dimensions for high performance connectors - grade 1, dimensional detail of standard test connectors - Grade 0, gauging information and tests selected from IEC 61169-1 applicable to all…
Radio-frequency connectors - Part 35: Sectional specification for 2,92 series RF connectors
IEC 61169-35:2011 provides information and rules for preparation of detail specification of 2,92 series RF coaxial connectors together with the pro-forma blank detail specification. It also prescribes mating face dimensions for high performance connectors - grade 1, dimensional detail of standard test connectors - Grade 0, gauging information and tests selected from IEC 61169-1 applicable to all…
ISO 7186:2011 specifies the requirements and test methods applicable to ductile iron pipes, fittings, accessories and their joints for the construction of drains and sewers outside buildings:
- to convey surface water (e.g. rainwater), domestic waste water and/or certain types of industrial effluents, either in separate systems or in combined systems;
- operating without pressure (gravity sewers…
Medical electrical equipment — Part 2-5: Particular requirements for the basic safety and essential ...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-5:2009.
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ULTRASONIC PHYSIOTHERAPY EQUIPMENT as defined in 201.3.216, hereafter referred to as
ME EQUIPMENT.
This standard only relates to ULTRASONIC PHYSIOTHERAPY EQUIPMENT employing a…
Medical electrical equipment — Part 2-41: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-41:2009.
201.1.1 *Scope
Replacement:
This particular standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of SURGICAL
LUMINAIRES AND LUMINAIRES FOR DIAGNOSIS, hereafter referred to as ME EQUIPMENT.
This particular standard does not apply to
– headlights;
– endoscopes, laparoscopes and…
Medical electrical equipment — Part 2-18: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-18:2009.
Clause 1 of the general standard1) applies, except as follows:
201.1.1 * Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ENDOSCOPIC EQUIPMENT together with its INTERCONNECTION CONDITIONS and INTERFACE
CONDITIONS.
The general…
Medical electrical equipment — Part 1-11: General requirements for basic safety and essential perfor...
This National Standard of Canada is equivalent to International Standard IEC 60601-1-11:2010.
1.1 * Scope
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
MEDICAL ELECTRICAL EQUIPMENT and MEDICAL ELECTRICAL SYSTEMS, hereafter referred to as
ME EQUIPMENT and ME SYSTEMS, which are intended by their MANUFACTURER for use in the
HOME HEALTHCARE ENVIRONMENT, as…
Medical electrical equipment — Part 2-52: Particular requirements for the basic safety and essential...
This National Standard of Canada is equivalent to International Standard IEC 60601-2-52:2009.
201.1.1 * Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
MEDICAL BEDS intended for adults, hereafter referred to as MEDICAL BED as defined in
201.3.212.
If a clause or subclause is specifically intended to be applicable to a MEDICAL BED only,…
Medical electrical equipment — Part 2-1: Particular requirements for thebasic safety and essential p...
201.1 Scope, object and related standards
Clause 1 of the general standard1) applies, except as follows:
201.1.1 Scope
Replacement:
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
ELECTRON ACCELERATORS, hereafter referred to as ME EQUIPMENT, in the range 1 MeV to
50 MeV, used for treatment of PATIENTS.
This particular standard, with the…