Medical electrical equipment — Part 2-8: Particular requirements for the basic safety and essential ...
This international standard applies to the basic safety and essential performance of
therapeutic X-RAY EQUIPMENT with NOMINAL X-RAY TUBE VOLTAGES in the range 10 kV to 1 MV
when connected to alternating current SUPPLY MAINS, hereafter referred to as ME EQUIPMENT.
NOTE This standard covers TELETHERAPY and BRACHYTHERAPY.
If a clause or subclause is specifically intended to be applicable to ME…
Medical electrical equipment — Part 2-23: Particular requirements for the basic safety and essential...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
TRANSCUTANEOUS PARTIAL PRESSURE MONITORING EQUIPMENT as defined in 201.3.63 and
hereinafter referred to as ME EQUIPMENT, whether this ME EQUIPMENT is stand alone or part of a
system.
This standard applies to transcutaneous monitors used with adults, children and neonates,
and it includes the use of these devices…
Medical electrical equipment — Part 2-4: Particular requirements for the basic safety and essential ...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of
CARDIAC DEFIBRILLATORS, hereafter referred to as ME EQUIPMENT.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies both to ME…
Medical electrical equipment — Part 2-28: Particular requirements forthe basic safety and essential ...
This International Standard applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of X-RAY
TUBE ASSEMBLIES and to components thereof:
– hereafter referred to as ME EQUIPMENT;
– intended for medical diagnosis and imaging.
If a clause or subclause is specifically intended to be applicable to ME EQUIPMENT only, or to
ME SYSTEMS only, the title and content of that clause or subclause will…
Electromagnetic compatibility of multimedia equipment - Emission requirements
CISPR 32:2012 International Standard applies to multimedia equipment (MME) having a rated r.m.s. AC or DC supply voltage not exceeding 600 V. Equipment within the scope of CISPR 13 or CISPR 22 is within the scope of this publication. MME intended primarily for professional use is within the scope of this publication. The radiated emission requirements in this standard are not intended to be…
Global maritime distress and safety system (GMDSS) - Part 6: Narrowband direct-printing telegraph eq...
IEC 61097-6:2005+A1:2011(E) Specifies the minimum performance requirements, technical characteristics and type-testing requirements for narrowband telegraph equipment for the reception of navigational and meteorological information as required by the International Convention for Safety of Life at Sea (SOLAS), and which is associated with IEC 60945. Also incorporates the performance standards of…
Water quality — The variability of test results and the uncertainty of measurement of microbiologica...
This International Standard gives guidelines for the evaluation of uncertainty in quantitative microbiological
analyses based on enumeration of microbial particles by culture. It covers all variants of colony count methods
and most probable number estimates.
Two approaches, the component (also known as bottom‑up or step‑by‑step) and a modified global (top‑down)
approach are included.
The aim is…
Photography — Electronic still picture imaging — Vocabulary
1 Scope
This International Standard defines terms used in electronic still picture imaging.
Only terms related to electronic still picture imaging are defined. These terms are relevant to current tasks or are of general interest in electronic still picture imaging.
Surface chemical analysis — Scanning-probe microscopy — Measurement of drift rate
ISO 11039:2012 defines terms and specifies measurement methods for characterizing the drift rates of scanning-probe microscopy (SPM) instruments in the X- and Y-directions and, for SPM instruments measuring topography, the drift rate in the Z-direction. Though the behaviour of the long-term drift rate might be nonlinear, both that and the behaviour of the short-term drift rate after a user-…
Dentistry — Manual toothbrushes — General requirements and test methods
This International Standard specifies requirements and test methods for the physical properties of manual toothbrushes in order to promote the safety of these products for their intended use.
This International Standard does not apply to manual interdental brushes and powered oral hygiene devices, as these instruments are covered by separate International Standards.