1.1 Généralités
Cette norme énonce les exigences de sécurité en matière d’électricité au travail qui visent à prévenir les
accidents pendant des activités comme l’installation, l’inspection, l’exploitation, l’entretien et le
démantèlement de conducteurs électriques et d’appareillage électriques et pendant les travaux effectués à
proximité d’appareillages électriques sous tension.
1.2…
Lamp controlgear — Part 2-13: Particular requirements for d.c. or a.c.supplied electronic controlgea...
This part of IEC 61347 specifies particular safety requirements for electronic controlgear for use on d.c.
supplies up to 380 V and a.c. supplies up to 600 V at 50 Hz or 60 Hz and at an output frequency that can
deviate from the supply frequency, associated with LED modules.
Note 1A: A lamp controlgear for LED modules may also be referred to as “LED controlgear”, “LED
driver”, “LED power…
1.1
Cette norme s’applique aux systèmes et à l’équipement électrique complets d’éoliennes prévus pour raccordement à des tensions maximales de 46 kV, et pour être utilisés conformément au Code canadien de l’électricité, Première partie. Les produits couverts par l’application de cette norme sont régis par les exigences de la CAN/CSA C22.2 n° 0.
1.2
Cette norme s’applique aux éoliennes de…
1.1
This Standard applies to the lines and equipment associated with underground electric supply and communication systems located entirely outside buildings and fenced supply stations.
This Standard, which forms part of the Canadian Electrical Code, Part III, covers the requirements for construction of underground systems and includes electric supply and communication circuits that are…
Specification for radio disturbance and immunity measuring apparatus and methods —
Part 1-1: Radio d...
This part of CISPR 16 specifies the characteristics and performance of equipment for the
measurement of radio disturbance in the frequency range 9 kHz to 18 GHz. In addition,
requirements are provided for specialized equipment for discontinuous disturbance
measurements.
NOTE In accordance with IEC Guide 107, CISPR 16-1-1 is a basic EMC standard for use by product committees
of the IEC. As stated…
1.1
This Standard applies to fans and ventilation equipment that is
a)
cord-connected, rated at not more than 250 V;
b)
permanently-connected to supply circuits of 600 V and less, single-phase or three-phase;
c)
used in non-hazardous locations;
d)
used in household, commercial, agricultural, or industrial locations;
e)
used indoors or outdoors; and
f)
used in accordance with the…
1.1
This Standard applies to motor-operated gardening appliances* intended for use on nominal system voltages of 250 V and less and in nonhazardous locations, and designed to be used in accordance with the Rules of the Canadian Electrical Code, Part I.
*For convenience, the short terms "appliance", "equipment", and "machine" are used herein.
1.2
This Standard…
Model Code for the field evaluation of medical electrical equipment and systems
1.1
This Model Code applies to the safety of medical electrical equipment (MEE) and medical electrical systems (MES) as it pertains to safety from electrical shock and fire and mechanical hazards. It provides construction, marking, and test requirements for the field evaluation of MEE and MES by a field evaluation body accredited by the SCC and/or recognized by the regulatory authority.…
Code modèle pour l’évaluation à pied d’oeuvre de l’appareillage et des systèmes électromédicaux
1.1
Ce code modèle s’applique à la sécurité des appareils électromédicaux (AEM) et des systèmes électromédicaux (SEM) en ce qui a trait aux dangers de choc électrique et d’incendie et aux dangers mécaniques. Il énonce les exigences de construction, de marquage et de mise à l’essai aux fins de l’évaluation à pied d’oeuvre des AEM et des SEM par un organisme d’évaluation à pied d’oeuvre accrédité…
La présente norme s’applique à quatre qualités d’essence sans plomb ni phosphore qui sont destinées à être
utilisées dans les moteurs à allumage commandé sous diverses conditions climatiques.
Cette norme ne s’applique pas au mélange d’essences et d’essences oxygénées qui s’effectue au point de vente
au détail ou après le point de vente au détail.
L’essence conforme à la présente norme peut…