Rechercher

Affiner les résultats
Code de la Classification internationale pour les normes (ICS)
Source
Code de l’organisme d’élaboration de normes (OEN)
Langue
Statut
Code de la Norme nationale du Canada (NNC)
Date de publication

De

à

Affichage 27711 - 27720 de 174248
Accessible design for the built environment
1 Scope 1.1 Purpose This Standard specifies technical requirements on how to make buildings and the exterior built environment accessible and safely usable by persons with physical, sensory, or cognitive disabilities. 1.2 Application This Standard describes technical requirements that can be used in the design and construction of new facilities or exterior environments, or in modifications to…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2018-10-31
Code(s) de l'ICS :
91.140.01
Systèmes de récupération d’eau de pluie
1 Portée 1.1 Inclusions 1.1.1 Applicabilité Les dispositions de cette norme s’appliquent à la conception, aux matériaux, à l’installation et à l’exploitation des systèmes de récupération d’eau de pluie pour les applications d’eau potable et non potable. 1.1.2 Sources d’eau Cette norme couvre l’utilisation de l’eau de pluie et de l’eau de ruissellement comme source d’eau. Note : L’eau de…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2018-10-31
Code(s) de l'ICS :
91.140.60
Cord sets and power-supply cords
1 Scope 1.1 This Standard specifies the requirements for cord sets and power-supply cords employing molded-on or assembled-on fittings, rated 600 V maximum, and intended for use in non-hazardous locations in accordance with CSA C22.1, Canadian Electrical Code, Part I, and CAN/CSA-C22.2 No. 0, General Requirements—Canadian Electrical Code, Part II. 1.2 This Standard also specifies the…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
29.060.10
Fire alarm and signal cable
1 Scope 1.1 This Standard applies to single- and multiple-conductor fire alarm and signal cables with a maximum nominal voltage rating of 300 V and a minimum temperature rating of 60 °C for use in buildings and other structures in dry, damp, or wet locations in accordance with the Canadian Electrical Code, Part I. 1.2 Because other CSA Group Standards specify requirements for certain…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
13.320
Photovoltaic (PV) module testing protocol for quality assurance programs
1 Scope 1.1 This Standard outlines a PV module testing protocol for quality assurance programs. It is intended to be used by financial institution and insurers, developers, independent engineers, and manufacturers. It provides best practices for photovoltaic module testing protocol for quality assurance programs. 1.2 This Standard is intended to be a stand-alone document that does not…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
27.160
Energy performance of refrigerated bottled or canned beverage vending machines
1 Scope 1.1 This Standard specifies energy performance requirements for self-contained, refrigerated bottled, or canned beverage vending machines that actively cool bottled, canned, or other sealed refrigerated beverages. 1.2 This Standard specifies a) uniform procedures for measuring energy consumption; b) maximum daily energy consumption levels; and c) refrigerated volume, vending…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
03.120.01; 03.120.01
Composite station post insulators This
1 Scope 1.1 This Standard specifies the electrical, mechanical, dimensional characteristics, test methods, and acceptance criteria for composite station post insulators for outdoor service, operating at nominal voltages greater than 1000 V and frequency not greater than 100 Hz. Station post insulators are mainly used as support or operating elements in switching equipment, or as bus bar or…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
29.035.99
Explosive atmospheres — Part 15: Equipment protection by type of protection “n” Atmosphères explos...
1 Scope This part of IEC 60079 specifies requirements for the construction, testing and marking for Group II electrical equipment with type of protection “n” which includes; sealed devices “nC”, hermetically sealed devices “nC”, non-incendive components “nC” and restricted breathing enclosures “nR” intended for use in explosive gas atmospheres. This part of CAN/CSA-C22.2 No. 60079 applies to…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
29.260.20
Cementitious materials compendium
1 Scope 1.1 This Standard addresses the following aspects of cementitious materials: a) their definitions; b) their chemical, physical, and uniformity requirements; c) the tests required; d) the procedures for inspection and sampling; and e) the units of measurement, packaging, marking, and storage. 1.2 The cementitious materials for use in concrete are classified as follows in this…
Éditeur :
CSA
Statut :
Annulée
Date de publication :
2018-10-31
Code(s) de l'ICS :
91.100.10
HDPE conduit, conductors-in-conduit, and fittings
1 Scope 1.1 This Standard applies to high density polyethylene (HDPE) conduit, HDPE conduit with conductors, and polyethylene dual-wall (PEDW) corrugated conduit, intended for use at a continuous operating temperature of 75 °C or 90 °C, for installation in accordance with the Rules of the Canadian Electrical Code, Part I, for direct burial or encasement in concrete or masonry in ordinary (non-…
Éditeur :
CSA
Statut :
Norme
Date de publication :
2018-10-31
Code(s) de l'ICS :
29.060.20

Spacer