Thermal-links — Requirements and application guide / Protecteurs thermiques — Exigences et guide d...
This International Standard is applicable to thermal-links intended for incorporation in
electrical appliances, electronic equipment and component parts thereof, normally intended
for use indoors, in order to protect them against excessive temperatures under abnormal
conditions.
NOTE 1 The equipment is not designed to generate heat.
NOTE 2 The effectiveness of the protection against…
Electric motor-operated hand-held tools, transportable tools and lawn and garden machinery — Safety ...
1 Scope
This clause of Part 1 is applicable, except as follows:
Addition:
This part of IEC 62841 applies to transportable drain cleaners.
NOTE 101 Drain cleaners are also known as pipe cleaners.
This standard does not apply to hand-held drain cleaners.
NOTE 102 Hand-held drain cleaners are covered by IEC 62841-2-21.
This standard does not apply to high pressure cleaners to clean drains.…
Outils électroportatifs à moteur, outils portables et machines pour jardins et pelouses — Sécurité —...
1 Domaine d'application
L'article de la Partie 1 s'applique avec les exceptions suivantes:
Addition:
La présente partie de l'IEC 62841 s'applique aux furets portables.
NOTE 101 Les furets sont également appelés "déboucheurs de canalisation".
La présente norme ne s'applique pas aux furets portatifs.
NOTE 102 Les furets portatifs sont couverts par l…
Performances photométriques des luminaires de route et de rue
1 Domaine d’application
1.1
Cette norme stipule les exigences relatives aux performances photométriques des luminaires utilisés pour l’éclairage des routes et des rues en fonction de la densité de puissance unitaire (DPU).
1.2
Les types de sources lumineuses suivants sont traités dans cette norme :
a)
lampe transparente à vapeur de sodium à haute pression (HPS);
b)
lampe transparente aux…
Explosive atmospheres — Part 13: Equipment protection by pressurized room “p” and artificially venti...
This part of IEC 60079 gives requirements for the design, construction, assessment,
verification and marking of rooms used to protect internal equipment:
– located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere (an area
normally requiring an equipment protection level (EPL) Gb, Gc, Db or Dc) without an
internal source of gas/vapour release and protected by pressurization…
Gas hose connectors for portable outdoor gas-fired appliances
1 Scope
1.1
This Standard applies to gas hose connectors (See Clause 3 Definitions), hereinafter referred to as connectors. They are conduits for conveying gas and depend for gas-tightness on the wall structure of the hose material. Such connectors are:
a)
newly produced and constructed entirely of new, unused parts and materials; and
b)
equipped with a fitting at each end provided with…
1 Scope
1.1
This Standard provides criteria and requirements for the design of a durable building and its building elements and includes provisions for cost analysis and management and for a quality management program for the design, construction, operation, maintenance, repair, and renovation of a building and its building elements.
1.2
This Standard applies to the building and to building…
1 Domaine d’application
Cette norme définit le terme « maison mobile de parc » utilisé dans la série de normes CSA Z241. Elle contient également les exigences de sécurité générales qui s’appliquent aux autres normes de cette série.
Standard for Pre-Engineered Dry and Wet Chemical Extinguishing System
1 Scope
1.1 These requirements cover the construction and operation of fixed pre-engineered dry chemical fire extinguishing system units and fixed automatic extinguisher units intended to be used in accordance with the Standard for Dry Chemical Extinguishing Systems, NFPA 17 and with the National Fire Code of Canada, asapplicable; and; fixedpre-engineered wet chemical fireextinguishing system…
Systèmes d'extinction d'incendie à poudres chimiques précalculés
1 Domaine d’application
1.1 Les présentes exigences s’appliquent à la construction et à l’utilisation des unités de système d’extinction àpoudrefixesstandardisées etdesunités desystèmed’extinction automatiquefixesconçues pour être utilisées en conformité avec la norme NFPA 17, Standard for Dry Chemical Extinguishing Systems, et avec le Code national de prévention des incendies du Canada, selon…