Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
IEC 61010-2-040:2020 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61010-2-040:2020 specifies safety requirements for electrical equipment intended for sterilization, washing,…
Organic light emitting diode (OLED) Light sources for general lighting - Safety - Part 1: General re...
IEC 62868-1:2020 specifies general safety requirements of OLED products for use on DC supplies up to 1000 V or AC supplies up to 1000 V at 50 Hz or 60 Hz for indoors and similar general lighting purposes.
This document applies to any OLED light sources which are not covered by IEC 62868-2 (all parts).
This first edition cancels and replaces IEC 62868 published in 2014.
Sources lumineuses électroluminescentes organiques (OLED) destinées à l’éclairage général - Sécurité...
L'IEC 62868-1:2020 spécifie les exigences générales de sécurité des produits OLED destinés à être utilisés avec des alimentations en tension continue jusqu’à 1000 V ou avec des alimentations en tension alternative jusqu’à 1000 V à 50 Hz ou 60 Hz, pour l’éclairage général intérieur ou similaire.
Le présent document s’applique aux sources lumineuses OLED qui ne sont pas couvertes par l’IEC…
Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 2-0...
IEC 61010-2-040:2020 specifies safety requirements for electrical equipment intended for sterilization, washing, and disinfection of medical materials in the medical, veterinary, pharmaceutical and laboratory fields, when used under the environmental conditions of 1.4. Examples of such equipment include the following:
- sterilizers and disinfectors using steam and/or hot water as the sterilant…
Exigences de sécurité pour appareils électriques de mesurage, de régulation et de laboratoire - Part...
L'IEC 61010-2-040:2020 définit les exigences de sécurité pour les appareils électriques destinés à la stérilisation, au lavage et à la désinfection du matériel médical dans les domaines médicaux, vétérinaires, pharmaceutiques et de laboratoire, lorsqu'ils sont utilisés dans les conditions d'environnement de 1.4. Exemples de ce type d'appareils:
- les stérilisateurs et…
Marine energy - Wave, tidal and other water current converters - Part 3: Measurement of mechanical l...
IEC TS 62600-3:2020 describes the measurement of mechanical loads on hydrodynamic marine energy converters such as wave, tidal and other water current converters (including river current converters) for the purpose of load simulation model validation and certification. This document contains the requirements and recommendations for the measurement of mechanical loads for such activities as site…
Plastiques — Détermination des caractéristiques au choc Charpy — Partie 2: Essai de choc instrumenté
1.1 Le présent document spécifie une méthode pour la détermination des propriétés des plastiques au choc Charpy à partir de diagrammes force/flèche. L'ISO 179-1 définit différents types d'éprouvettes en forme de barreau, diverses configurations d'essai, ainsi que les paramètres d'essai à adopter suivant le type de matériau, d'éprouvette et d'entaille.
En outre, le…
Non-destructive testing of welds — Ultrasonic testing — Use of time-of-flight diffraction technique ...
This document specifies the application of the time-of-flight diffraction (TOFD) technique to the semi- or fully automated ultrasonic testing of fusion-welded joints in metallic materials of minimum thickness 6 mm.
It applies to full penetration welded joints of simple geometry in plates, pipes, and vessels, where both the weld and the parent material are low-alloyed carbon steel. Where specified…