Low-voltage controlgear. Part 2: Semiconductor contactors (solid state contactors)
Applies to semiconductor contactors intended for performing electrical operations by changing the state of electric circuits between on state and off state. The main circuit of the semiconductor contactors is intended to be connected to circuits the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.
Appareillage de commande à basse tension. Deuxième partie: Contacteurs à semiconducteurs (contacteur...
S'applique aux contacteurs à semi-conducteurs destinés à effectuer des manoeuvres électriques en changeant l'état des circuits électriques, les faisant passer de l'état passant à l'état bloqué. Le circuit principal des contacteurs à semi-conducteurs est destiné à être relié à des circuits dont la tension nominale ne dépasse pas 1 000 V en courant alternatif ou 1 500 V en…
Supplement F - Essential ratings and characteristics et
semiconductor devices and genera...
Applies to the storage, transport, handling and testing of electrostatic sensitive devices: the discharge of electrostatic energy from unearthed equipment or operators produces voltages that could destroy the device, even if the device contains protection circuits.
Magnetic materials - Part 4: Methods of measurement of the d.c. magnetic properties of solid steels
Describes the terminology and two measuring methods, namely: the ring method and the permeameter method. Both methods use a test specimen in a closed magnetic circuit. Description of the test equipment and the electric circuits is given.
Rotating electrical machines - Part 14: Mechanical vibration of certain machines with shaft heights ...
Applies to d.c. and three-phase a.c. machines, with shaft heights 56 mm and higher and a rated power up to 50 MW, at nominal speeds from 600 rev/min up to and including 3 600 rev/min. For vertical machines, applies to those machines which are measured in a state of free suspension, and excludes those exceeding a shaft height of 400 mm. The contents of the corrigendum of August 1984 have been…
Machines électriques tournantes - Partie 14: Vibrations mécaniques de certaines machines de hauteur ...
Applicable aux machines à courant continu et à courant alternatif triphasé de hauteur d'axe supérieure ou égale à 56 mm jusqu'à une puissance assignée de 50 MW, à des vitesses nominales de 600 tr/min. Pour les machines verticales, cette norme n'est applicable qu'à celles qui sont mesurées en état de suspension libre et exclut celles de hauteur d'axe supérieure à 400 mm.…