Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equi...
IEC 61000-3-2:2018 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It…
Batteries for Use in Stationary, Vehicle Auxiliary Power and Light Electric Rail (LER) Applications
1 Scope
1.1 These requirements cover battery systems as defined by this standard for use as energy storage for
stationary applications such as for PV, wind turbine storage or for UPS, etc. applications. These systems
shall be installed in accordance with NFPA 70, C22.1, or other applicable installation codes.
1.2 These requirements also cover battery systems as defined by this standard for…
Batteries destinées aux appareils stationnaires, à l’alimentation auxiliaire pour véhicules et aux a...
1 Domaine d’application
1.1 Les exigences suivantes s’appliquent aux systèmes de batteries, tels qu’ils sont définis dans la
présente norme, conçus à des fins de stockage de l’énergie pour des applications stationnaires,
notamment pour le stockage de l’énergie pour les systèmes photovoltaïques ou les éoliennes, ou pour
l’alimentation sans coupure. Ces systèmes doivent être installés…
Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equi...
IEC 61000-3-2:2018 deals with the limitation of harmonic currents injected into the public supply system. It specifies limits of harmonic components of the input current which can be produced by equipment tested under specified conditions. It is applicable to electrical and electronic equipment having a rated input current up to and including 16 A per phase, and intended to be connected to public…
Compatibilité électromagnétique (CEM) - Partie 3-2 : Limites - Limites pour les émissions de courant...
L’IEC 61000-3-2:2018 traite de la limitation des courants harmoniques injectés dans le réseau public d’alimentation. Elle définit les limites des harmoniques du courant d’entrée qui peuvent être produits par les matériels soumis à l’essai dans des conditions spécifiées. La présente partie de l’IEC 61000 est applicable aux appareils électriques et électroniques ayant un courant d’entrée assigné…
Household and similar electrical appliances - Safety - Part 2-40: Particular requirements for electr...
IEC 60335-2-40:2018 deals with the safety of electric heat pumps, including sanitary hot water heat pumps, air conditioners, and dehumidifiers incorporating motor-compressors and hydronic fan coils units, their maximum rated voltages being not more than 250 V for single phase appliances and 600 V for all other appliances. Partial units are within the scope of this International Standard.…
Appareils électrodomestiques et analogues - Sécurité - Partie 2-40 : Exigences particulières pour le...
L'IEC 60335-2-40:2018 traite de la sécurité des pompes à chaleur électriques, notamment les pompes à chaleur pour production d'eau chaude sanitaire, les climatiseurs et les déshumidificateurs qui comportent des motocompresseurs et des ventiloconvecteurs hydroniques, dont la tension assignée maximale n'est pas supérieure à 250 V pour les appareils monophasés et à 600 V pour tous les…
Automatic electrical controls - Part 2-9: Particular requirements for temperature sensing controls
IEC 60730-2-9:2015+A1:2018 applies to automatic electrical temperature sensing controls for use in, on or in association with equipment, including electrical controls for heating, air-conditioning and similar applications. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof. This standard is applicable to automatic electrical temperature…