Fine ceramics (advanced ceramics, advanced technical ceramics) — Characteristic of piezoelectric pro...
This document specifies a method of measuring piezoelectric properties of piezoelectric fine ceramics and other piezoelectric devices. It applies to electrical transient response methods for evaluating the piezoelectric properties of piezoelectric fine ceramics resonators under high vibration levels.
Récipients et accessoires pour produits injectables — Partie 1: Flacons en verre étiré
Le présent document spécifie la forme, les dimensions et les capacités des flacons en verre pour préparations injectables. Il spécifie également le matériau constitutif de ces flacons et les exigences de performance relatives à ces récipients.
Le présent document est applicable aux récipients en verre blanc ou ambré, en verre borosilicaté ou en verre de silicate sodocalcique, obtenus à partir de…
NORME SUR LA CONFIGURATION ET L’EXPLOITATION DE CENTRALES DE RÉCEPTION D’ALARME
1 DOMAINE D’APPLICATION
1.1 Cette norme aborde les exigences relatives aux centrales de réception d’alarmes, aux services de
protection, aux centrales de service, aux centres satellites, aux centres de saisie de données à distance,
aux centrales de réception d’alarme hébergées, aux centrales de réception de signaux vidéo gérés et aux
centres de transition.
1.2 Cette norme aborde les…
STANDARD FOR SIGNAL RECEIVING CENTRES CONFIGURATIONS AND OPERATIONS
1 SCOPE
1.1 This Standard covers requirements applicable to signal receiving centre facilities, protection service,
service centres, satellite centres, remote data entry centres, hosted signal receiving centres, managed
video signal receiving centres and bridging centres.
1.2 This standard covers the requirements for alarm-guard response service.
1.3 This Standard does not include…
Fibrocement drain, waste, and vent pipe and pipe fittings
1 Scope
1.1
This Standard covers fibrocement Type 1 (Class 3000) and Type 2 (Class 4000) pipe and pipe fittings for installation in gravity-flow systems inside and outside of buildings, above and below grade.
1.2
This Standard includes specifications for material, dimensions, crushing strength, chemical resistance, and joint tightness. Methods of marking to indicate compliance with these…
Guideline on basement flood protection and risk reduction
1.1 General
This Guideline covers measures to reduce the risks of basement flooding, and to mitigate the adverse effects on property, public safety, and public health in case of a flood event. It covers existing, new, rebuilt, and renovated houses in rural and urban settings.
1.2 Buildings covered
This Guideline covers all types of ground-related houses, with or without basements, that…
This standard describes two grades of propane used for fuel purposes. These grades consist mainly of hydrocarbons
containing three carbon atoms.
Grade 1 is intended for use in internal combustion engines and for general industrial and commercial fuel applications.
Grade 1 maintains a minimum octane quality by limiting concentrations of low-octane components (see 6.5).
NOTE The requirements…
La présente norme s’applique à deux grades de propane utilisés comme carburant. Ces grades sont principalement
constitués d’hydrocarbures comptant trois atomes de carbone.
Le propane de grade 1 est destiné aux moteurs à combustion interne et peut servir de carburant dans des
applications industrielles et commerciales de nature générale. Il conserve un indice d’octane minimal en limitant la…
1 Domaine d’application
1.1
Cette norme vise le retraitement sécuritaire, efficace et fiable des dispositifs médicaux réutilisables à
chaque étape du déroulement des travaux de retraitement, y compris
a) l’établissement d’un SGQ applicable à un SRDM, y compris :
i) les indicateurs de performance clés;
ii) les politiques et les modes opératoires;
iii) la documentation;
iv) les rôles et…
Automatic electrical controls — Part 2-9: Particularrequirements for temperature sensing controls
1.1 Scope
[Add the following paragraph]
This Standard applies to the safety of such equipment designed and constructed for installation and use
in accordance with CSA C22.1, Canadian Electrical Code, Part I.