Dispositifs de commande électrique automatiques à usage domestique et analogue - Partie 2-14 : Règles particulières pour les actionneurs électriques

Logo
CSA Group
Organisme d'élaboration de normes:
Programme de travail:
Numéro de référence:
CAN/CSA-E60730-2-14:13
Catégorie de norme:
Norme nationale du Canada - Adoption d'une Norme internationale
Type d’activité d’élaboration de normes:
Confirmation
Statut:
En cours d'élaboration
Date de début de la période de commentaires OEN:
Date de fin de la période de commentaires des OEN:
Affiché le:

Porté:

Champ d’application

This clause of part 1 is applicable except as follows:

1.1 Replacement:

This part of IEC 60730 applies to electric actuators for use in, on, or in association with equipment for household and similar use for heating, air-conditioning and ventilation. The equipment may use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof.

This part 2 applies to electric actuators using NTC or PTC thermistors, additional requirements for which are contained in annex J.

1.1.1 This part 2 applies to the inherent safety, to the operating values, operating times and operating sequences where such are associated with equipment safety and to the testing of electric actuators used in, on or in association with, equipment for household and similar use for heating, air-conditioning and ventilation.

Requirements for specific operating values, operating times and operating sequences may be given in the standards for appliances and equipment.

Throughout this part 2 the word "equipment" means "appliance and equipment".

Electric actuators for equipment not intended for normal household use, but which nevertheless may be used by the public, such as equipment intended to be used by laymen in shops, in light industry and on farms, are within the scope of this part 2.

This part 2 does not apply to electric actuators designed exclusively for industrial applications.

This part 2 does not apply to electric actuators which are mechanically integral with valves.

See IEC 60730-2-8, Particular requirements for electrically operated valves, including mechanical requirements and IEC 60730-2-17, Particular requirements for electrically operated gas valves.

This part 2 does not apply to electric motors, requirements for which are contained in IEC 60034.

1.1.2 Requirements for manual switches not integral with an electric actuator are contained in IEC 61058-1.

1.2 Replacement

This part 2 applies to electric actuators with a rated voltage not exceeding 690 V and with a rated current not exceeding 63 A.

1.3 Replacement

This part 2 does not take into account the response value of an automatic action of an electric actuator, if such a response value is dependent upon the method of mounting the electric actuator in the equipment. Where a response value is of significant purpose for the protection of the user, or surroundings, the value defined in the appropriate household equipment or as determined by the manufacturer shall apply.

1.4 Replacement:

This part 2 applies also to electric actuators incorporating electronic devices, requirements for which are contained in annex H

Raison d’être du projet

Raison d’être du projet
na

Note : L’information ci-dessus a été recueillie et est diffusée par le Conseil canadien des normes (CCN) pour les besoins de son système de notification centralisé et transparent pour l’élaboration de nouvelles normes. Le système permet aux organismes d’élaboration de normes (OEN) accrédités par le CCN et aux membres du public d’être informés des nouveaux travaux d’élaboration de normes au Canada. Il donne aussi aux OEN accrédités la possibilité de repérer et de résoudre les cas de doubles emplois éventuels dans les normes et les travaux de normalisation.

Les OEN sont eux-mêmes responsables du contenu et de l’exactitude de l’information présentée ici. Cette information n’existe que dans la langue dans laquelle elle a été fournie au CCN.