1 Scope
1.1 This Standard applies to luminaires for use in non-hazardous locations and that are intended for
installation on branch circuits of 600 V nominal or less between conductors in accordance with the
Canadian Electrical Code, Part I (CEC), CSA C22.1, with the U. S. National Electrical Code (NEC),
ANSI/NFPA 70, and with the Mexican National Electrical Code, NOM-001-SEDE.
1.2 This…
Optical amplifiers - Test methods - Part 1-3: Power and gain parameters - Optical power meter method
IEC 61290-1-3:2021 applies to all commercially available optical amplifiers (OA) and optically amplified subsystems. It applies to OA using optically pumped fibres (OFA based on either rare-earth doped fibres or on the Raman effect), semiconductors (SOA), and waveguides (POWA).
NOTE 1 The applicability of the test methods described in this document to distributed Raman amplifiers is for further…
Amplificateurs optiques - Méthodes d'essai - Partie 1-3: Paramètres de puissance et de gain - M...
L'IEC 61290-1-3:2021 s’applique à tous les amplificateurs optiques (AO) et sous-systèmes à amplification optique, disponibles sur le marché. Elle s’applique aux AO utilisant des fibres pompées optiquement (AFO basé sur des fibres dopées aux terres rares ou sur l’effet Raman), des semiconducteurs (AOS), et des guides d’ondes (POWA).
NOTE 1 L’applicabilité des méthodes d’essai décrites dans…
Code sur les chaudières, les appareils et les tuyauteries sous pression
1 Domaine d’application
1.1
Sous réserve de l’article 1.2, la première partie de cette norme s’applique à toutes les chaudières, tous les appareils sous pression, toutes les tuyauteries sous pression et aux accessoires régis par la loi (et définis à l’article 3) et indiqués dans la première partie de cette norme.
Notes :
1)
Les lois ou les règlements des provinces et des territoires…
Code sur les établissements d’entretien de véhicules au propane
1 Domaine d’application
1.1 Inclusions
Ce code s’applique aux zones des établissements d’entretien de véhicules motorisés, y compris aux zones et aux systèmes attenants, où s’effectue l’entretien ou la réparation de véhicules au propane ou leur entreposage lorsque ces véhicules sont entretenus ou réparés. Cela s’applique lorsque le circuit de carburant est utilisé pour assurer la force motrice…
Optical amplifiers - Test methods - Part 1-3: Power and gain parameters - Optical power meter method
IEC 61290-1-3:2021 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61290-1-3:2021 applies to all commercially available optical amplifiers (OA) and optically amplified subsystems…
Requirements for bodies providing audit and certification of information security management systems...
This document specifies requirements and provides guidance for bodies providing audit and certification of a privacy information management system (PIMS) according to ISO/IEC 27701 in combination with ISO/IEC 27001, in addition to the requirements contained within ISO/IEC 27006 and ISO/IEC 27701. It is primarily intended to support the accreditation of certification bodies providing PIMS…
Matériel de protection des cultures — Systèmes de transfert fermés (STF) — Spécification des perform...
Le présent document spécifie les exigences de sécurité, eu égard de l'opérateur et de l'environnement, ainsi que les moyens de contrôle de la conformité, concernant la conception et la fabrication de systèmes de transfert fermés (STF) destinés à des produits de protection des plantes (PPP), sous forme liquide, contenus dans des bidons de 1 l à 20 l de capacité.
Il spécifie en outre le…
Equipment for crop protection — Closed transfer systems (CTS) — Performance specification
This document specifies operator and environment-related safety requirements and the means of their verification for the design and construction of closed transfer systems (CTS) for liquid formulations of plant protection products (PPP) in 1 l to 20 l containers.
In addition, it specifies the type of information on safe working practices including information about residual risks to be provided…